期刊文献+

Computer-aided 3-D reconstruction and measurement of the optic canal and intracanalicular structures 被引量:1

Computer-aided 3-D reconstruction and measurement of the optic canal and intracanalicular structures
原文传递
导出
摘要 Objective To reconstruct the human optic canal and its inner structures, and to provide detailed knowledge of this region for optic nerve decompression for further understanding on the pathologic mechanisms of indirect optic nerve injury Methods Six optic canals and their inner structures were reconstructed using a computer aided 3 dimensional reconstruction system Quantitative measurement of the canal wall thickness, bony canal transverse area, optic nerve transverse area, dural sheath transverse area, subarachnoid space transverse area, and subarachnoid space volume were done by means of the computer morphometric analysis system The detailed spatial relationship among intracanalicular structures were also carefully identified on the 3 D models Results The thinnest portion of the canal was the middle part of the medial wall (0 45±0 35?mm) and the narrowest space was in the middle part of the optic canal (the transverse area was 18 21±2 50?mm 2) The volume of subarachnoid space which can be considered the compensatory space for distention incurred by the hemorrhage, optic nerve edema, or hematoma was 21 16±4 31?mm 3 At the cranial opening ,the middle part and orbital opening, its transverse area was 4 45±1 12?mm 2, 2 68±1 32?mm 2 and 1 23±0 83?mm 2, respectively Conclusions Since the compensatory space was limited, even a tiny amount of blood or swelling of the nerve may cause optic nerve compression Because the narrowest space was in the middle part of the optic canal and the compensatory space for distention gradually decreases from cranial end to orbital end, the middle part and the anterior part of the optic canal and dural sheath are critical in optic nerve decompression Objective To reconstruct the human optic canal and its inner structures, and to provide detailed knowledge of this region for optic nerve decompression for further understanding on the pathologic mechanisms of indirect optic nerve injury Methods Six optic canals and their inner structures were reconstructed using a computer aided 3 dimensional reconstruction system Quantitative measurement of the canal wall thickness, bony canal transverse area, optic nerve transverse area, dural sheath transverse area, subarachnoid space transverse area, and subarachnoid space volume were done by means of the computer morphometric analysis system The detailed spatial relationship among intracanalicular structures were also carefully identified on the 3 D models Results The thinnest portion of the canal was the middle part of the medial wall (0 45±0 35?mm) and the narrowest space was in the middle part of the optic canal (the transverse area was 18 21±2 50?mm 2) The volume of subarachnoid space which can be considered the compensatory space for distention incurred by the hemorrhage, optic nerve edema, or hematoma was 21 16±4 31?mm 3 At the cranial opening ,the middle part and orbital opening, its transverse area was 4 45±1 12?mm 2, 2 68±1 32?mm 2 and 1 23±0 83?mm 2, respectively Conclusions Since the compensatory space was limited, even a tiny amount of blood or swelling of the nerve may cause optic nerve compression Because the narrowest space was in the middle part of the optic canal and the compensatory space for distention gradually decreases from cranial end to orbital end, the middle part and the anterior part of the optic canal and dural sheath are critical in optic nerve decompression
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2000年第2期44-47,共4页 中华医学杂志(英文版)
基金 ThisresearchwassupportedbyMilitaryMedicalandHygienic"95Project"ResearchGrant PLA China (No 96Z0 5 7)
关键词 optic canal · optic nerve · computer aided · 3 D reconstruction optic canal · optic nerve · computer aided · 3 D reconstruction
  • 相关文献

参考文献6

  • 1Maniscalco JE,Habal MB.Microanatomy of optic canal[].Journal of Neurosurgery.1978
  • 2Dai P,Jian SC,Gu R,et al.Computer-aided threedimensional reconstruction and measurement of bony and membranous labyrinth[].Chinese Medical Journal.1994
  • 3Kuppersmith RB,Alford EL,Patrinely JR,et al.Combined transconjunctival/ intranasal endoscopic approach to the optic canal in traumatic optic neuropathy[].Laryngoscope.1997
  • 4Mauriello JA,Deluca J,Krieger A,et al.Management of traumatic optic neuropathy—a study of 23 patients[].British Journal of Ophthalmology.1992
  • 5Habal MB,Maniscalco JE,Lineaweaver WC.Microsurgical anatomy of the optic canal: anatomical Relations and Exposure of the optic nerve[].Surgical Forum.1976
  • 6Warner J,Lessell S.Traumatic optic neuropathy[].International Ophthalmology Clinics.1995

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部