期刊文献+

Relation between sound transfer function from diffuse sound field to the eardrum and temporary threshold shift

Relation between sound transfer function from diffuse sound field to the eardrum and temporary threshold shift
原文传递
导出
摘要 Twelve volunteers with normal hearing (9 males and 3 females) participated in this work The sound transfer functions (STFS) from diffuse sound field to the subject's eardrums were measured and correlated to the temporary threshold shift (TTS) due to fiffuse-exposure.A probe tube with a miniature microphone was used for STF measurements in which successive 1/3 oct bandwidth random noise with central frequency from 0.25 kKz to 8 kHz were used. The subjects were divided into two groups, with the STF maxima at 2 kHz and 4 kHz respectively Pre- and post- exposure sweep Bekesy audiograms were recorded and the temporary thresh old shift calctilated as the difference between the two. Frequency of the maximum TTS was correlated to that of the maximum STF. The average TTS was very small or zero at frequen cies below the band noise exposure , but was noticeable even at the highest measured frequency (8 kHz) for beyond the noise band. Also individual differences in STF were found at frequencies between 2 kHz and 4 kHz Twelve volunteers with normal hearing (9 males and 3 females) participated in this work The sound transfer functions (STFS) from diffuse sound field to the subject's eardrums were measured and correlated to the temporary threshold shift (TTS) due to fiffuse-exposure.A probe tube with a miniature microphone was used for STF measurements in which successive 1/3 oct bandwidth random noise with central frequency from 0.25 kKz to 8 kHz were used. The subjects were divided into two groups, with the STF maxima at 2 kHz and 4 kHz respectively Pre- and post- exposure sweep Bekesy audiograms were recorded and the temporary thresh old shift calctilated as the difference between the two. Frequency of the maximum TTS was correlated to that of the maximum STF. The average TTS was very small or zero at frequen cies below the band noise exposure , but was noticeable even at the highest measured frequency (8 kHz) for beyond the noise band. Also individual differences in STF were found at frequencies between 2 kHz and 4 kHz
出处 《Chinese Journal of Acoustics》 1999年第3期259-265,共7页 声学学报(英文版)
  • 相关文献

参考文献14

  • 1Hudde H.Estimation of the area function of human ear canals by sound pressure measurements.J Acoast. Society of America . 1983
  • 2Shaw E A G,Teranishi R.Sound pressure generated in an external ear replica and real human ears by a nearby point source. The Journal of The Acoustical Society of America .
  • 3Stinson M R,khanna S M.Sound propagation in the ear canal and coupling to the eardrum, with measurements of model systems. The Journal of The Acoustical Society of America . 1989
  • 4Villchur E,Killion M C.Probe tube microphone assembly J Acoust. Society of America . 1975
  • 5Stinson M R.The spacial distribution of sound pressure within scaled replicas of the human ear canal. The Journal of The Acoustical Society of America . 1985
  • 6Rodriguez G P Gerhardt K J.Influence of outer ear resonant frequency on patterns of temporary threshold shift. Ear and Hearing . 1991
  • 7Hellstrom P A,Axelsson A.Miniatur microphone probe tube measurements in the external auditory canal. The Journal of The Acoustical Society of America . 1993
  • 8Mehrgardt S,Mellert V.Transformation characteristics of the external human ear. The Journal of The Acoustical Society of America . 1977
  • 9Gallo R,Glorig A.Permanent threshold shift changes produced by noise exposure and aging. American Industrial Hygiene Association Journal . 1964
  • 10Caiazzo A J,Tonndorf J.Ear canal resonance and TTS. The Journal of The Acoustical Society of America . 1977

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部