某电厂位于长江南岸的长江大堤堤内圩区。属长江河漫滩地貌单元。厂区分布第四系冲积物及牛轭湖相沉积层, 基岩为第三系红层。通过工程地质钻探、原位测试、土工试验、综合试桩及复合地基试验。对区内淤泥质土进行岩土工程特性分析, 提出岩土工程设计所需各种参数和地基处理建议方案。
Some Power Plant was situated in dike area of the south bank of a Yangtse River,belong in valley flat geomorphic unit.Plant area was distributed over Quaternary system alluvium and deposit of oxbow lake facies,base rock is Tertiary red rock.By engineering geologyical drilling、in situ test、soil test、synthetic test pile and test of composite foundation,analyze the mucky soil for geotechnical engineering specific poperty,raise every parameter was in demand of geotechnical engineering design,and proposed plan of foundation treatment.
出处
《电力勘测设计》
1999年第4期15-17,共3页
Electric Power Survey & Design
关键词
淤泥质土
综合试桩
复合地基