摘要
以河北万全化工厂生产过程中排出的高浓度含氰废水为研究对象,采用酸性条件下吹脱氧化法进行处理,研究温度、pH值、曝气量、曝气时间等因素对处理效果的影响,并提出了采用该项技术的运行参数。
With the high-concentrated cyanide wastewater produced during the producing process of Wan Quan chemical. Industrial Factory as object, the method of Blowdown-and-Oxidization was been carried out, and the influences of temperature, pH, the amount and time of aeration on the treatment effect are studied.
出处
《河北建筑工程学院学报》
CAS
1999年第4期1-5,共5页
Journal of Hebei Institute of Architecture and Civil Engineering
关键词
含氰废水
吹脱氧化
温度
pH值
曝气量
曝气时间
Cyanide wastewater, Blowndown and Oxidization, temperature, pH, amount and time of aeration