摘要 目的 按照无应力遮挡原理 ,设计一种治疗尺骨鹰嘴骨折的新型的无应力遮挡的外固定器 ,使其取得更佳的临床疗效。方法 应用该外固定器治疗 2 2例尺骨鹰嘴骨折患者。结果  2 2例术后随访 3个月至 1.5年 ,骨折解剖对位 ,愈合 ,功能完全恢复 ,无任何并发症和后遗症。结论 本外固定器不仅具有微创、固定可靠、早期关节活动及无须行内固定取出术、操作简便安全、并发症少等优点 ,同时还具有设计原理新颖 ,拓展性强等特点。从骨折治疗的进展看 。 Objective An external fixator was designed for curing the ulna olecranon fracture according to the principle of non-stress shelter.Methods Non-stress Shielding external fixator was used in 22 clinical ulna olecranon fracture cases.Results Clinical follow-up survery from 3 to 18 months, the patients had attained bone healing with anatomic paraposition, the elbow function complete recoved, and without any complication or sequela.Conclusion The new non-stress Shielding external fixator has the virtue of minimally invasive, fixation reliable, earlier joint functional training and need not remove the internal fixator, operation convenient and less complication.The external fixator design principl accord to the doctrine of Biological Osteosynthesis (BO) and can be used in other fracture.
作者 陈建鸿 李昂
出处 《实用骨科杂志》 2004年第2期109-111,共3页 Journal of Practical Orthopaedics
关键词 无应力遮挡 外固定器 治疗 尺骨鹰嘴骨折 肘关节内骨折 ulna olecranon fracture non-stress shielding external fixator
  • 相关文献

参考文献2

  • 1孟和 黄克勤.骨折复位固定器疗法[M].天津科技出版社,1995.122.
  • 2天津医院骨科.中西结合治疗骨折[M].北京:人民卫生出版社,1995.122-130.

共引文献1

同被引文献13

  • 1王岩,主译.坎贝尔骨科手术学[M].第11版.北京:人民军医出版社,2009:12.
  • 2Sahajpal D, Wright TW. Proximal ulna fractures. Journal of Hand Surgery [J]. American Volume,2009,34 (2): 357-362.
  • 3Browner BD, Jupiter JB, Trafton PG, et aLSkeletal trauma[M]. 2nd ed. Beijing:Science Press, 2001:1467.
  • 4Sultan S, Khan AZ. management of comminuted fractures of the olecranon by tension band wiring [J]. J Ayub Med Coll Abbottabad, 2003,15 (3) :27-29.
  • 5Douglas T, Daniel S,Ha G,et aL Cyclic loading of olecra- non fracture fixation constructs [J]. The Journal Of Bone And Joint Surgery,2003, ( 85 ): 831-837.
  • 6Elliott M J, Ruland R, Fox B. Olecranon fracture fixation utilizing a bioabsorbable tension band construct: analysis of stability with motion in a cadaveric model [ J ]. J Pediatr Orthop B,2005,14(6):444-447.
  • 7Buijze GA, Blankevoort L, Tuijthof GJ, et al.Biomechani- cal evaluation of fixation of comminuted olecranon frac- tures: one-third tubular versus locking compression plating [J].Archives of orthopaedic and trauma surgery,2010,130 (4) :459-464.
  • 8Nowak TE;Burklart KJ;Mueller LP, et al.New intramedul- lary locking nail for olecranon fracture fixation-an in vitro biomeehanical comparison with tension band wiring [J].J Trauma,2010,69 ( 5 ) :56-61.
  • 9Molloy S,Jasper LE,Elliott DS,ct al. Biomechanical evalua- tion of intramedullary nail versus tension band fixation for transverse olecranon fractures [J]. J Orthop Trauma,2004, 18(3):170-174.
  • 10Iannuzzi N, Dahners L.Excision and advancement in the treatment of comminuted olecranon fractures [ J ]. J Orthop Trauma,2009,23 (3) :226-228.

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部