期刊文献+

Loss of Coolant Experiments for the Test Nuclear Heating Reactor

Loss of Coolant Experiments for the Test Nuclear Heating Reactor
原文传递
导出
摘要 A series of tests were completed for three types of loss of coolant accidents (LOCAs) (pipe break in the gas plenum. near the liquid level and submerged under water) in the test nuclear heating reactor (NHR). Experiments show that the three cases of LOCAs (loss of coolant accidents) have different patterns. In the case of a pipe break connected to the gas plenum, the quantity of water lost is independent of the diameter of the broken pipe. In the case of a pipe located near the liquid level. the quantity of water lost depends on the location of the pipe. In the case of a pipe break below the water level. all the water above the break will be discharged. The discharge patterns for all three cases are analyzed in detail. A series of tests were completed for three types of loss of coolant accidents (LOCAs) (pipe break in the gas plenum. near the liquid level and submerged under water) in the test nuclear heating reactor (NHR). Experiments show that the three cases of LOCAs (loss of coolant accidents) have different patterns. In the case of a pipe break connected to the gas plenum, the quantity of water lost is independent of the diameter of the broken pipe. In the case of a pipe located near the liquid level. the quantity of water lost depends on the location of the pipe. In the case of a pipe break below the water level. all the water above the break will be discharged. The discharge patterns for all three cases are analyzed in detail.
出处 《Tsinghua Science and Technology》 SCIE EI CAS 1996年第1期32-35,共4页 清华大学学报(自然科学版(英文版)
关键词 loss of coolant nuclear heating reactor pipe break loss of coolant nuclear heating reactor pipe break
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部