摘要
The coolant thermal mixing performance in the hot gas plenum (HGP) in the core bottom reflector of the 10MW high temperature gas-cooled reactor test module (HTR-10) was experimentally investigated on a 1:1.5 scale test model. The experimental results show that the HGP installed with a radial partition static mixer results in excellent thermal mixing of the coolant with a nondimensional temperature mixing degree (ε) value of 94%. Within the Re range from 1. 4 ×105~5. 8×105, the ε value reaches 94% at the outlet of the HGP and 99% at the outlet of the hot gas duct (HGD). There is little influence of the inlet flow rate ratio. Gh/Ge. on the thermal mixing performance in the Gh/Ge range from 0.5~2.0.
The coolant thermal mixing performance in the hot gas plenum (HGP) in the core bottom reflector of the 10MW high temperature gas-cooled reactor test module (HTR-10) was experimentally investigated on a 1:1.5 scale test model. The experimental results show that the HGP installed with a radial partition static mixer results in excellent thermal mixing of the coolant with a nondimensional temperature mixing degree (ε) value of 94%. Within the Re range from 1. 4 ×105~5. 8×105, the ε value reaches 94% at the outlet of the HGP and 99% at the outlet of the hot gas duct (HGD). There is little influence of the inlet flow rate ratio. Gh/Ge. on the thermal mixing performance in the Gh/Ge range from 0.5~2.0.