摘要
根据抽油电机的工作特性,提出了无功动态补偿新技术方案。分析了供电系统与抽油电机的电气特性,利用坐标变换,将三相瞬时电压、电流转换到α-β平面,得到瞬时虚功率。用电容补偿瞬时无功功率,从而达到提高瞬时功率因数,节约电能的目的。
This paper will put forward a new technical plan which is concerned with dynamicreactive power compensation according to the characteristic of an electric motor forpumping oil. First, the characteristic of a power supply system and the motor is anal-ysed, then in terms of coordinate alternating, three-phase intantaneous electric currentand voltage are varied onto α-β plane, thus intantaneous imaginary power is gained. Atlast, electric capacity is made use of to compensate the imaginary power, so that powerfactor can be raised and electric power can be saved.
出处
《大庆石油学院学报》
CAS
北大核心
1993年第1期118-121,共4页
Journal of Daqing Petroleum Institute
关键词
功率因数
动态补偿
抽油机
电动机
pumping units
power factor
coordinate transformations
[kineticstate compensation]