EXPERIMENTAL STUDY ON THE OCCLUSION OF ARTERIAL BLOOD FLOW BY THE IMPLANTATION OF NITINOL ALLOY STENTS

EXPERIMENTAL STUDY ON THE OCCLUSION OF ARTERIAL BLOOD FLOW BY THE IMPLANTATION OF NITINOL ALLOY STENTS
原文传递
导出
摘要 To evaluate the occlusion of arteries, 6 conic intravascular endoprosthetic stents of titanium-nickel alloy were implanted translnminally to the right external iliac arteries in 2 normal dogs and 4 normal pigs. The stent was characterized by ductility below 313 K (40℃) and restoration memory-shape between 313-319 K. The diameter of the large end of come stent was 4.0 mm (dog) and 4.5 mm(pig). The topographic anatomy showed that the external iliac artery was near complete occlusion, with a very small residual lumen (about 1 mm in diameter) in dogs at 6 months, with complete occlusion in pigs at 8 months. The histopathological examination indicated that the arterial intima of the upper branch from the stented site was smooth, and that neither inflammatory cell infiltration nor foreign giant cell reaction was found. The newly formed granulation tissue inside the stent came from emboli organization. These results suggest that the shape-memory alloy stent has good biocompatibility and the conic intravascular endoprosthetic stent might completely occlude arterial blood flow. To evaluate the occlusion of arteries, 6 conic intravascular endoprosthetic stents of titanium-nickel alloy were implanted translnminally to the right external iliac arteries in 2 normal dogs and 4 normal pigs. The stent was characterized by ductility below 313 K (40℃) and restoration memory-shape between 313-319 K. The diameter of the large end of come stent was 4.0 mm (dog) and 4.5 mm(pig). The topographic anatomy showed that the external iliac artery was near complete occlusion, with a very small residual lumen (about 1 mm in diameter) in dogs at 6 months, with complete occlusion in pigs at 8 months. The histopathological examination indicated that the arterial intima of the upper branch from the stented site was smooth, and that neither inflammatory cell infiltration nor foreign giant cell reaction was found. The newly formed granulation tissue inside the stent came from emboli organization. These results suggest that the shape-memory alloy stent has good biocompatibility and the conic intravascular endoprosthetic stent might completely occlude arterial blood flow.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 1994年第7期34-36,共3页 中华医学杂志(英文版)
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部