速度编码电影MR评价心室每搏输出量的可重复性研究 被引量:1

Reproducible study of ventricular function with velocity encoded cine MR
下载PDF
导出
摘要 目的 探讨速度编码电影MR成像技术在评价心室每搏输出量测量中的应用价值。方法 应用速度编码电影MR(VECMR)对 9例健康成年志愿者进行心脏检查。重复测量左、右心室每搏输出量 (SV)以比较其观察者间、观察者内测量的重复性 ,并与形态体积法电影MR测得的结果进行比较。结果 ①VECMR测量左、右心室每搏输出量观察者间及观察者内重复性高 ,相关性好。②该方法与形态体积法MR所测正常成人左、右心室SV相关性良好 ,相关系数分别为 0 .98和0 .96,两种方法测得的SV均值比较 ,差异无显著性意义 (P >0 .0 5 )。结论 速度编码电影MR测量心室每搏输出量准确 ,重复性高 ,检查简便、省时 。 Objective To investigate the value of velocity encoded cine magnetic resonance imaging (VECMR) in assessment of ventricular stroke volume (SV). Methods Nine cases of healthy adults volunteer were studied with VECMR. The SVs of the left and right ventricle were measured respectively by two observers and one observer in two different times for evaluating the inter-observer reproducibility and the intra-observer reproducibility. Both ventricular SVs were also compared with those by stereological cine magnetic resonance imaging (SCMRI). Results To SVs of both ventricle in adults volunteer with VECMR, the inter-observer reproducibility and the intra-observer reproducibility were good enough, the measurements of two observers were correlated well, the measurements of two times by one observer were also correlated well. The SVs of the left and right ventricle using both VECMR and SCMRI were agreed well, and the correlative coefficient was 0.97 and 0.96 respectively, there was no significant statistical difference ( P >0.05). Conclusion VECMR is an accurate, convenient and reproducible measuring method for evaluating the ventricular function and has a more practical value in clinics.
出处 《中国医学影像技术》 CSCD 2004年第6期894-897,共4页 Chinese Journal of Medical Imaging Technology
关键词 速度编码 磁共振成像 可重复性 方法 Velocity encoded cine Magnetic resonance imaging Reproducibility Methods
  • 相关文献

参考文献9

  • 1[1]Sakuma H, Kawada N, Takeda K, et al. MR measurement of coronary blood flow[J]. J Magn Reson Imaging, 1999, 10(5): 728-733.
  • 2[2]Grist TM, Polzin JA, Bianco JA, et al. Measurement of coronary blood flow and flow reserve using magnetic imaging[J]. Cardiology, 1997, 88(2): 80-89.
  • 3[3]Chatzimvroudis GP, Walker PG, Oshinski JN, et al. Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping[J]. Magn Reson Med, 1997,37(4): 545-551.
  • 4[4]Wolf RL, Ehman RL, Riedercr SJ, et al. Analysis of systemic and random error in MR volumetric flow measurements[J]. Magn Reson Med, 1993, 30(1): 82-91.
  • 5[5]Hofman MB, Visser FC, van Rossum AC, et al. In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels[J]. Magn Reson Med, 1995,33(6): 778-784.
  • 6[6]Chatzimavroudis GP, Zhang HS, Halliburton SS, et al. Clinical blood flow quantification with segmented k-space magnetic resonance phase velocity mapping[J]. J Magn Reson Imaging, 2003,17(1) :65-71.
  • 7[7]Tang C, Blatter DD, Parlcer DL. Accuracy of phase-contrast flow measurements in the presence of partial volume effects[J] . J Magn Reson Imaging, 1993,3(2): 337-385.
  • 8[8]Buonocore MH, Bogren H. Factors influencing the accuracy and precision of velocity-encoded phase imaging[J]. Magn Reson Med,1992,26(1): 141-154.
  • 9[9]Greil G, Geva T, Maier SE, et al. Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements[J]. J Magn Reson Imaging, 2002,15(1): 47-54.

同被引文献38

  • 1郝兴海,徐敏,郑慧萍,高峰,崔仲奇,高文德,杨碧波.指端容积脉搏曲线法与Swan-Ganz导管法心血管功能监测的临床对照研究[J].医疗装备,2005,18(7):6-8. 被引量:7
  • 2白净,吴冬生.桡动脉脉搏波的仿真模型[J].航天医学与医学工程,1995,8(2):94-98. 被引量:12
  • 3王舒,张素品,赵玉庆,李文硕.体表超声法与经气管多普勒法测定心输出量的相关性研究及临床评价[J].中国急救医学,1995,15(6):10-14. 被引量:3
  • 4滕晓菲,张元亭.移动医疗:穿戴式医疗仪器的发展趋势[J].中国医疗器械杂志,2006,30(5):330-340. 被引量:84
  • 5Weinbroum AA, Biderman P, Softer D, et al. Reliability of cardiac output calculation by the tick principle and central venous oxygen saturation in emergency conditions [ J]. Journal of Clinical Monitoring and Computing, 2008, 22 (5) : 361 - 366.
  • 6Cholley BP, Singer M. Esophageal doppler: noninvasive cardiac output monitor [ J ]. ECHOCARDIOGRAPHY-A Jml. of CV Ultrasound & Allied Tech, 2003, 20(8) : 763 -769.
  • 7Vahier B, Cholley BP, Belot JP, et al. Noninvasive monitoring of cardiac output in critically ill patient using transesophageal doppler [ J]. American Journal of Respiratory and Critical Care Medicine, 1999, 159:77 - 83.
  • 8Kondo C, Caputo GR, Semelka R, et al. Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation [ J]. American Journal of Roentgenology, 1991, 157:9 - 16.
  • 9Reddy GP. Cardiac MRI: Techniques [ OL]. http://www. radiology. ucsf. edu/chest/sites/radiology. ucsf. edu. chest/ files/Kuwait%201. pdf, 2008-02-29/2010-01-10.
  • 10Capek JM, Roy RJ. Noninvasive measurement of cardiac output using partial CO2 rebreathing ~ J ]. IEEE Transactions on Biomedical Engineering, 1988, 35(9) : 653 -661.

引证文献1

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部