摘要
根据自动喷水灭火系统设计规范规定的计算方法,对各项水力计算推导了一个统一的模式,并列出了适用于不同危险等级和负荷喷头数的各项综合系数,从而仅需根据工程条件,选用相应的系数代入简化公式,即可一次求得系统所需的总供水压力值。
On the basis of calculation method stipulated in the design code of sprinkler system,a unified hydraulic calculation mode was deduced with respect to every item,whose composite index was listed according to danger degree and the quantity of sprinkler head,from which the total pressure can be evaluated by means of determining corresponding coefficient according to the engineering conditions.
出处
《给水排水》
CSCD
1992年第5期32-36,3,共6页
Water & Wastewater Engineering