气垫式调压室水击穿室的研究 被引量:2

Research on Water Hammer through Air Cushion Surge Chambers
下载PDF
导出
摘要 从水击基本方程出发,考虑了气垫式调压室内水击波的反射作用,用分析法推出了穿室压力系数的公式,采用数值解法,并编制了计算程序、进行计算及分析了各种因素对穿室压力系数的影响。 As the reflection of water hammer waves in an air cushion surge chamber has been taken into account, the formula of water hammer pressure coefficient through it is derived by analytical methods from water hammer equations by using numerical analysis in this paper. Computer programs are drawn up to calculate water hammer pressure coefficient through it and various factors of influence on it are considered.
出处 《人民珠江》 1992年第5期27-33,共7页 Pearl River
关键词 气垫式调压窒 水击穿室 穿室压力系数 阻抗式调压室 Air cushion surge chamber Water hammer through the chamber Coefficient of water hammer pressure through the chamber Throttled surge chamber