期刊文献+

The prediction of the peak width at half height in HPLC

The prediction of the peak width at half height in HPLC
全文增补中
导出
摘要 The prediction of the peak width at half height is an important aspect in the optimization of the chromatographic operating conditions.In this paper,a linear relationship,between the peak widths at half height and the retention values with various isocratic elution is observed.In gradient elution,however,the relationship between the peak widths at half height and the so-called invented retention values that correspond to the mobile phase composition by eluting the solute from the column end is developed.We believe that there is almost the same band width at half height inside the column (in unit of length)for different solutes.The peak width at half height in the chromatogram(in unit of time)is mainly determined by the capacity factor of the solute when it is eluted front the column end.The larger the capacity factor of a solute eluted from the column end,the more slowly will be the solute eluted from the column end and the wider will be the peak width at half height.It is possible to predict the peak width at half height in various isocratic and gradient elutions by using this linear relationship. The prediction of the peak width at half height is an important aspect in the optimization of the chromatographic operating conditions.In this paper,a linear relationship,between the peak widths at half height and the retention values with various isocratic elution is observed.In gradient elution,however,the relationship between the peak widths at half height and the so-called invented retention values that correspond to the mobile phase composition by eluting the solute from the column end is developed.We believe that there is almost the same band width at half height inside the column (in unit of length)for different solutes.The peak width at half height in the chromatogram(in unit of time)is mainly determined by the capacity factor of the solute when it is eluted front the column end.The larger the capacity factor of a solute eluted from the column end,the more slowly will be the solute eluted from the column end and the wider will be the peak width at half height.It is possible to predict the peak width at half height in various isocratic and gradient elutions by using this linear relationship.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1991年第3期237-244,共0页 中国化学(英文版)
基金 This work was supported by the Foundation of Chinese Academy of Sciences.
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部