无外荷载作用下钢筋混凝土支撑温度效应分析 被引量:2

Analysis of temperature stress in reinforced concrete strut under no external loads
原文传递
导出
摘要 以一不受外荷载作用的钢筋混凝土支撑梁为试验对象,利用自动化监测技术采集其在大气环境作用下的轴力和温度变化数据。基于试验数据,考察了不同截面位置对温度应力的影响,定性比较了4个不同厂商的钢筋应力计抗"温度应力"的性能,并探讨了温度应力与温差之间的关系。结果表明:温差大的截面位置会产生较大的温度应力,截面上部温度应力最大、下部次之、中部最小;厂商三的应力计的抗"温度应力"的性能具有一定的优势,厂商一的应力计略逊于厂商三的应力计;温度应力与温差并非是简单的线性关系。 A reinforced concrete strut under no external loads was exposed to the atmospheric environment.And automatic monitoring technology was used to collect the data of axial force and temperature.Based on the experimental data,the effect of different section position on temperature stress was studied,the temperature stress resistance ability of reinforcement stress meter of four different manufacturers was compared qualitatively,and the relationship between temperature stress and temperature difference was investigated.The results show that: a.temperature stress will be larger when temperature difference at the section position is larger,so the temperature stress at the section upper is the largest,while that at the section center take the second place,and that at the section bottom is the least;b.the reinforcement stress meter of NO.3 company has advantages in resistance ability of temperature stress,and the meter of NO.1 company slightly inferior to it;c.the relationship between temperature stress and temperature difference is not the simple linear relation.
出处 《工业建筑》 CSCD 北大核心 2013年第S1期603-606,共4页 Industrial Construction
关键词 动化监测 温度应力 温差 automatic monitoring temperature stress temperature difference
  • 相关文献

参考文献7

二级参考文献25

  • 1姚甫昌,谢红建,何世秀.对修正剑桥模型的认识及试验模拟[J].湖北工学院学报,2004,19(1):13-16. 被引量:9
  • 2张中普,姚笑青.某深基坑事故分析及技术处理[J].施工技术,2005,34(12):72-73. 被引量:21
  • 3孙钧.地下工程设计理论与实践[M].上海科学技术出版社,1995..
  • 4郑刚 顾晓鲁.基坑支护设计规范试算报告.中国建筑学会地基基础专业委员会学术会议暨地基规范修订会议[M].广州,1998..
  • 5王建林 郑刚 等.温差对基坑系统内力的影响.第一届全国基坑工程学术会议论文集[M].北京:建筑技术杂志社,1998..
  • 6郑刚 顾晓鲁 等.温度变化对基坑支护结构的影响分析.中国土木工程学会第八届全国土力学及岩土工程学术会议论文集[M].南京:万国学术出版社,1999..
  • 7DBJ08-61-97上海市基坑工程设计规程条文[S]
  • 8Chapman K R, Cording E J, Schnabel H. Performance of a braced excavation in granular and cohesive soils [C]// ASCE Specialty Conference on Performance of Earth and Earth-Supported Structures. Purdue University, 1972: 271-293
  • 9邵乃辰.差动式仪器的温度补偿问题[J].大坝观测技术,2007,2.
  • 10中国建筑科学研究院,中华人民共和国建设部.JGJl2-1999建筑基坑支护技术规程[S].北京:中国建筑工业出版社,1999.