期刊文献+

VDW Raypex5根尖定位仪测量根管工作长度的准确性评价 被引量:2

下载PDF
导出
摘要 根管治疗术是牙髓病和根尖周病等首选的最佳方法,其成功与否取决于充分的根管预备、冲洗以及完善的根管充填,要达到这些要求,准确地确定根管的工作长度是关键所在。常用测量根管工作长度的方法有手感法、电测法及X线插针照相法等,其中电测法因其使用方便、准确性高、X线的辐射量少等优点受到临床医师的普遍欢迎。笔者研究VDW Raypex 5根尖定位仪测量根管工作长度的准确率,目的是探求一种简便、准确、快捷的测量方法,从而提高根管治疗成功率。
作者 王红 曹正山
出处 《中国医药导刊》 2013年第S1期123-124,共2页 Chinese Journal of Medicinal Guide
  • 相关文献

参考文献3

二级参考文献8

共引文献8

同被引文献27

  • 1Stoll R, Urban-Klein B, Roggendorf M J, et al. Effective- ness of four electronic apex locators to determine distance from the apical foramen [J]. Int Endod J,2010,43(9): 808-817.
  • 2Deka A,Bhuyan AC, Bhuyan D. A comparative evaluation of root canal area increase using three different nickel-ti- tanium rotary systems:an ex vivo cone-beam computed tomographie analysis [J]. Contemp Clin Dent,2015,6(1): 79-83.
  • 3Sahar-Helft S,Sarp AS,Stabholtz A,et al. Comparison of positive -pressure ,passive ultrasonic, and laser -activated irrigations on smear-layer removal from the root canal sur- face [J]. Photomed Laser Surg,2015,33(3) : 129-135.
  • 4Dua A,Dua D. Comparative evaluation of efficacy of En- doVac irrigation system to Max-! probe in removing smear layer in apical 1 mm and 3 mm of root canal:an in vitro scanning electron microscope study [J]. Dent Res J:Isfa- han,2015,12(1) :38-43.
  • 5Raghu KN, Daniel JG, Razvi S, et al. In vivo evaluation of the accuracy of working length determination using an electronic apex locater IPEX (NSK) on vital uninfected teeth and teeth with radiographic evidence of periapical lesions [J]. J Int Soc Prev Community Dent,2014,4(Suppl 3) : S204-S208.
  • 6Dukic W,Delija B,Derossi D,et al. Radiopacity of com- posite dental materials using a digital X-ray system [J]. Dent Mater J, 2012,31 ( 1 ) : 47-53.
  • 7Ray DS,Wiemann AH,Patel PB,et al. Estimation of the rate of tooth wear in permanent incisors: a cross-sec- tional digital radiographic study [J]. J Oral Rehabil,2015, 42 (6) : 460-466.
  • 8Khursheed I, Bansal R, Bansal T, et al. A comparative e-valuation of working length with digital radiography and third generation apex locator (ProPex)in the presence of various intracanal irrigants: An in vivo/ex vivo study [J]. Dent Res J : Isfahan, 2014,11 ( 1 ) : 56-60.
  • 9Chakravarthy Pishipati KV. An in Vitro comparison of propex II apex locator to standard radiographic method [J]. Iran Endod J,2013,8(3) : 114-117.
  • 10Sadeghi S,Abolghasemi M. The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file [J]. Med Oral Patol Oral Cir Bucal, 2010, 15 (5) : e788-e790.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部