关节镜辅助下撬拨复位经皮螺钉内固定治疗SchatzkerⅢ型胫骨平台骨折 被引量:4

原文传递
导出
摘要 胫骨平台凹陷性骨折为关节内骨折,治疗不当易发生创伤性关节炎、关节僵硬等并发症。笔者自2010年10月~2012年3月应用膝关节镜辅助下撬拨复位经皮螺钉内固定治疗18例SchatzkerⅢ型胫骨平台骨折,报告如下。1临床资料1.1一般资料本组18例,男10例,女8例;年龄20~50岁,平均36岁。受伤原因:车祸伤10例,坠落伤3例,扭伤5例。合并半月板损伤6例,前交叉韧带止点撕脱1例。
出处 《中国骨与关节损伤杂志》 2013年第S1期127-127,共1页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献4

二级参考文献20

  • 1Sehatzker J,McBroom R,Bruee D.The fibial-teaufraeture:the toronto experience 1968-1975.Clin Orthop, 1979,138:94.
  • 2Merchant TC, Dietz FK.Long-term follow-up after fractures of the taland fibular shaft.J Bone Joint Surg(Am), 1989,71(4) :599.
  • 3Lachiewic ZP ,Fundk T.Factors influencing the resultof open reduction and internal fixation of tibial plateau fracture.Clin Orthop, 1984,182: 193.
  • 4Trenholm A,Landry S, Mclauglhin K,et al.Comparative fLxation of tibial plateau fractures using alpha-BSM, a calcium phosphate cement, versus cancellous bone graft.J Orthop Trauma, 2005,19:698.
  • 5Keating JF,Hajducka CL,Harper J.Minimor internal fixation and calum-phosphate cement in the treatment of fracture of tibial plateau. J Bone Joint Surg(Am),2003,85:68.
  • 6Weigel DP,Marsh JL.High-energy fractures of the tibal plateau knee function after longer follow-up.j Bone Joint Surg(Am),2002,84: 1541-1551.
  • 7Cole PA,Zlowodzki IM,Kregor PJ.Less invasive stabilization system (LISS) for fractures of the proximal tibia:indications,surgical technique and preliminary results of the UMC clinical trial.Injury, 2003,34 (1):16-29.
  • 8Ando T, Nishihara K. Arthroscopic internal fixation of fractures of the intercondylar eminence of the tibia. Arthroscopy, 1996; 12(5):616.
  • 9Mah JY, Otsuka NY, McLean J. An arthroscopic technique for the reduction and fixation of tibial-eminence fractures. J Pediatr Orthop, 1996; 16(1):119.
  • 10Osti L, Merlo F, Liu SH, et al. A simple modified arthroscopic procedure for fixation of displaced tibial eminence fractures.Arthroscopy, 2000; 16(4):379.

共引文献89

同被引文献35

  • 1Schatzker J, Mcbroom R,Bruce D. The tibial plateau fracture. The Toronto experience 1968:1975[J]. Clin Orthop, 1979,138:94-104.
  • 2Weigel DP,Marsh JL. High-energy fractures of the tibial plateau knee function after longer follow-up [J]. J Bone Joint Surg(Am), 2002,84 : 1541-1551.
  • 3Kubiak EN,Camuso MR,Barei DP,et a/. Operative treatment of ip- silateral noncontiguous unicondylar tibial plateau and shaft frac- tures:combining plates and nails [J]. J Orthop Trauma,2008,22(8): 560-565.
  • 4Barei DP,Nork SE,Mills WJ,et al. Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures u- tilizing a two-incision technique [J]. J Orthop Trauma,2004,18(10): 649-657.
  • 5Boldin C ,Fankhauser F,Hofer HP,et al. Three-year results of proxi- mal tibia fractures treated with the LISS [J]. Clin Orthop Relat Res, 2006,445 : 222-229.
  • 6Bone LB ,Johnson KD. Treatment of tibial fractures by reaming and intramedullary nailing[J]. J Bone Joint Surg(Am), 1986,68(6) :877- 887.
  • 7Jiang R,Luo CF, Wang MC, eta/. A comparative study of Less Inva- sire Stabilization System (LISS) f'Lxation and two-incision double plating for the treatment of bicondylar tibial plateau fractures [J]. Knee ,2008,15(2): 139-143.
  • 8Lubowitz JH,Elson WS,Gtuttmann D. Arthroscopic management of tibia[ plateau fractures[J]. Arthroscopy,2004,20:1063-1070.
  • 9Suganuma J,Akutsu S. Arthroscopically assisted treatment of tibial plateau fcaetures[J]. Arthroscopy ,2004,20:1084-1089.
  • 10卢世璧,王岩,周勇刚,等.坎贝尔骨科手术学[M].第11版.人民军医出版社,2009:2474—2475.

引证文献4

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部