期刊文献+

Efficacy of cap-assisted endoscopy for routine examining the ampulla of Vater

Efficacy of cap-assisted endoscopy for routine examining the ampulla of Vater
下载PDF
导出
摘要 AIM: To determine the efficacy of a cap-assisted endoscopy (CAE) to completely visualize the ampulla of Vater (AV) in patients failed by conventional endoscopy. METHODS: A prospective study was conducted on 120 patients > 20 years of ages who visited the Health Promotion Center of Chungbuk National University Hospital for conscious sedation esophagogastroduodenoscopy (EGD) as a screening test from July to October, 2011. First, forward-viewing endoscopy was performed with reasonable effort using a push and pull method. We considered complete visualization of the AV when we could observe the entire AV including the orifice clearly, and reported the observation as complete or incomplete (partial or not found at all). Second, in cases of complete failure of the observation, an additional AV examination was conducted by attaching a short cap (D-201-10704, Olympus Medical Systems, Tokyo, Japan) to the tip of a forward-viewing endoscope. Third, if the second method failed, we replaced the short cap with a long cap (MH-593, Olympus Medical Systems) and performed a re-examination of the AV. RESULTS: Conventional endoscopy achieved complete visualization of the AV in 97 of the 120 patients (80.8%) but was not achieved in 23 patients (19.2%). Age (mean ± SD) and gender [male (%)] were not significantly different between the complete observation and the incomplete observation groups. Additional short CAE was performed in patients in whom we could not completely visualize the AV. This group included 13 patients (10.9%) with partial observation of the AV and 10 (8.3%) in which the AV was not found. Short CAE permitted a complete observation of the AV in 21 of the 23 patients (91.3%). Patients in whom visualization of the AV failed with short CAE had satisfactory outcomes by replacing the short cap with a long cap. The additional time for CAE took an average of 141 ± 88 s. There were no complications and no significant mucosal trauma. CONCLUSION: CAE is safe to use as a salvage method to achieve complete visualization of the AV when a regular EGD examination fails. AIM: To determine the efficacy of a cap-assisted endoscopy (CAE) to completely visualize the ampulla of Vater (AV) in patients failed by conventional endoscopy. METHODS: A prospective study was conducted on 120 patients > 20 years of ages who visited the Health Promotion Center of Chungbuk National University Hospital for conscious sedation esophagogastroduodenoscopy (EGD) as a screening test from July to October, 2011. First, forward-viewing endoscopy was performed with reasonable effort using a push and pull method. We considered complete visualization of the AV when we could observe the entire AV including the orifice clearly, and reported the observation as complete or incomplete (partial or not found at all). Second, in cases of complete failure of the observation, an additional AV examination was conducted by attaching a short cap (D-201-10704, Olympus Medical Systems, Tokyo, Japan) to the tip of a forward-viewing endoscope. Third, if the second method failed, we replaced the short cap with a long cap (MH-593, Olympus Medical Systems) and performed a re-examination of the AV. RESULTS: Conventional endoscopy achieved complete visualization of the AV in 97 of the 120 patients (80.8%) but was not achieved in 23 patients (19.2%). Age (mean ± SD) and gender [male (%)] were not significantly different between the complete observation and the incomplete observation groups. Additional short CAE was performed in patients in whom we could not completely visualize the AV. This group included 13 patients (10.9%) with partial observation of the AV and 10 (8.3%) in which the AV was not found. Short CAE permitted a complete observation of the AV in 21 of the 23 patients (91.3%). Patients in whom visualization of the AV failed with short CAE had satisfactory outcomes by replacing the short cap with a long cap. The additional time for CAE took an average of 141 ± 88 s. There were no complications and no significant mucosal trauma. CONCLUSION: CAE is safe to use as a salvage method to achieve complete visualization of the AV when a regular EGD examination fails.
出处 《World Journal of Gastroenterology》 SCIE CAS 2013年第13期2037-2043,共7页 世界胃肠病学杂志(英文版)
基金 Supported by Grant of the Korea Healthcare Technology R and D Project, Ministry of Health and Welfare, South Korea, No.A100054
关键词 AMPULLA of VATER Conventional ENDOSCOPY Cap-assisted ENDOSCOPY Screening test Complete oservation Ampulla of Vater Conventional endoscopy Cap-assisted endoscopy Screening test Complete observation
  • 相关文献

参考文献7

  • 1Hyung Hun Kim,Seun Ja Park,Moo In Park,Won Moon,Sung Eun Kim.Transparent-cap-fitted colonoscopy shows higher performance with cecal intubation time in difficult cases[J].World Journal of Gastroenterology,2012,18(16):1953-1958. 被引量:7
  • 2Hoi-Poh Tee,Crispin Corte,Hamdan Al-Ghamdi,Emilia Prakoso,John Darke,Raman Chettiar,Wassim Rahman,Scott Davison,Sean P Griffin,Warwick S Selby,Arthur J Kaffes.Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs standard colonoscopy[J].World Journal of Gastroenterology,2010,16(31):3905-3910. 被引量:10
  • 3Tae Hoon Lee,Byoung Wook Bang,Jee In Jeong,Hyung Gil Kim,Seok Jeong,Seon Mee Park,Don Haeng Lee,Sang-Heum Park,Sun-Joo Kim.Primary endoscopic approximation suture under cap-assisted endoscopy of an ERCP-induced duodenal perforation[J].World Journal of Gastroenterology,2010,16(18):2305-2310. 被引量:19
  • 4Ji Suk Kwon,Eun Soo Kim,Kwang Bum Cho,Kyung Sik Park,Woo Young Park,Jeong Eun Lee,Tae Yol Kim,Byoung Kuk Jang,Woo Jin Chung,Jae Seok Hwang.Incidence of Propofol Injection Pain and Effect of Lidocaine Pretreatment During Upper Gastrointestinal Endoscopy[J].Digestive Diseases and Sciences.2012(5)
  • 5A. Trecca,F. Gaj,G. Gagliardi,K. Fu,T. Fujii.Our experience with endoscopic repair of large colonoscopic perforations and review of the literature[J].Techniques in Coloproctology.2008(4)
  • 6Dr. Masanori Tada M.D.,Haruhiro Inoue M.D.,Eiich Yabata M.D.,Satoshi Okabe M.D.,Mitsuo Endo M.D.Feasibility of the transparent cap-fitted colonoscope for screening and mucosal resection[J].Diseases of the Colon & Rectum.1997(5)
  • 7Haruhiro Inoue,Mitsuo Endo,Kimiya Takeshita,Kunihide Yoshino,Yukihiko Muraoka,Hideo Yoneshima.A new simplified technique of endoscopic esophageal mucosal resection using a cap-fitted panendoscope (EMRC)[J].Surgical Endoscopy.1992(5)

二级参考文献28

  • 1Lieberman DA,Weiss DG,Bond JH,Ahnen DJ,Garewal H,Chejfec G. Use of colonoscopy to screen asymptomatic adults for colorectal cancer. Veterans Affairs Cooperative Study Group 380. N Engl J Med 2000; 343: 162-168.
  • 2Imperiale TF,Wagner DR,Lin CY,Larkin GN,Rogge JD, Ransohoff DF. Risk of advanced proximal neoplasms in asymptomatic adults according to the distal colorectal find- ings. N Engl J Med 2000; 343: 169-174.
  • 3Rex DK,Johnson DA,Lieberman DA,Burt RW,Sonnenberg A. Colorectal cancer prevention 2000: screening recommen- dations of the American College of Gastroenterology. Ameri- can College of Gastroenterology. Am J Gastroenterol 2000; 95: 868-877.
  • 4Byeon JS,Yang SK,Kim TI,Kim WH,Lau JY,Leung WK, Fujita R,Makharia GK,Abdullah M,Hilmi I,Sollano J,Yeoh KG,Wu DC,Chen MH,Kongkam P,Sung JJ. Colorectal neo- plasm in asymptomatic Asians: a prospective multinational multicenter colonoscopy survey. Gastrointest Endosc 2007; 65: 1015-1022.
  • 5Rex DK,Bond JH,Winawer S,Levin TR,Burt RW,Johnson DA,Kirk LM,Litlin S,Lieberman DA,Waye JD,Church J,Marshall JB,Riddell RH. Quality in the technical perfor- mance of colonoscopy and the continuous quality improve- ment process for colonoscopy: recommendations of the U.S. Multi-Society Task Force on Colorectal Cancer. Am J Gastro- enterol 2002; 97: 1296-1308.
  • 6Rex DK,Petrini JL,Baron TH,Chak A,Cohen J,Deal SE, Hoffman B,Jacobson BC,Mergener K,Petersen BT,Safdi MA,Faigel DO,Pike IM. Quality indicators for colonoscopy. Am J Gastroenterol 2006; 101: 873-885.
  • 7Barclay RL,Vicari JJ,Doughty AS,Johanson JF,Greenlaw RL. Colonoscopic withdrawal times and adenoma detec- tion during screening colonoscopy. N Engl J Med 2006; 355: 2533-2541.
  • 8Rex DK. Achieving cecal intubation in the very difficult co- lon. Gastrointest Endosc 2008; 67: 938-944.
  • 9Dafnis G,Granath F,P?hlman L,Ekbom A,Blomqvist P. Pa- tient factors influencing the completion rate in colonoscopy. Dig Liver Dis 2005; 37: 113-118.
  • 10Church JM. Complete colonoscopy: how often? And if not, why not? Am J Gastroenterol 1994; 89: 556-560.

共引文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部