摘要
本文通过理论计算与反向热泄漏测量、冰箱实际运行热泄露测量相结合的方法来测算冰箱的热负荷,评估箱体的绝热性能,并考虑与冰箱的制冷系统相匹配,从而得到冰箱各工况下各部位最佳泡层厚度,使整个系统的能效最优。
Through the combined method of theoretical calculation,thermal leakage reversing measurement and practical operation measurement,we measure the heat load of the direct cooling refrigerator.The paper evaluates adiabatic performance and takes into account matching the foam thickness with the cooling system of the refrigerator.It draws the conclusion of the best conditions of foam thickness and optimal energy consumption of the entire system.
出处
《电器》
2013年第S1期134-137,共4页
China Appliance
关键词
泡层优化
直冷冰箱
热负荷
冰箱性能评价
Foam optimization
Direct cooling refrigerators
Heat load
Refrigerator performance Evaluation