调强适形放射治疗剂量验证方法分析与改进
摘要
调强适形放射治疗(intensity modulated radiation therapy,IMRT)是三维适形放疗的一种重要方法,它能更有效地避开邻近靶区周围的危急器官,提高靶区的剂量而达到治疗目的;但同时所要求的精度更高[1-2].
出处
《中华放射医学与防护杂志》
CAS
CSCD
北大核心
2008年第2期-,共2页
Chinese Journal of Radiological Medicine and Protection
参考文献7
-
1Ezzell GA,Galvin JM,Low DA. Guidance document on delivery,treatment planning,and clinical implementation of IMRT:Report of the IMRT subcommittee of the AAPM radiation therapy committee[J].Medical Physics,2003,(08):2089-2115.doi:10.1118/1.1591194.
-
2Intensity Modulated Radiation Therapy Collaborative Working Group. Intensity-modulated radiotherapy:current status and issues of interest[J].International Journal of Radiation Oncology,Biology,Physics,2001,(04):880-914.
-
3Low DA,Gerber RL,Mutic S. Phantoms for IMRT dose distribution measurement and treatment verification[J].Int J Rediet Oncd Biol Phys,1998,(05):1231-1235.doi:10.1016/S0360-3016(97)00910-3.
-
4李勤,韩军,孙长庚,伍钢,邓光宇.个体化调强适形放疗计划剂量验证方法的建立[J].中华放射医学与防护杂志,2007,27(2):170-172. 被引量:6
-
5Agazaryan N,Solberg TD,DeMarco JJ. Patient specific quality assurance for the delivery of intensity modulated radiotherapy[J].Journal of Applied Clinical Medical Physics,2003,(01):40-50.doi:10.1120/1.1525243.
-
6IAEA. IAEA Technical Reports Series No,277.Absorbed dose determination in photon and electron beams-an internation code of practice[M].Vienna:IAEA,1997.
-
7IEC. IEC 60731,Medical electrical equipment,dosimeters with ionization chambers as used in radiotherapy[M].Geneva:IEC,1997.
二级参考文献10
-
1戴建荣,胡逸民,张红志,关莹,张可,王闯.针对患者调强放射治疗计划的剂量学验证[J].中华放射肿瘤学杂志,2004,13(3):229-233. 被引量:65
-
2Burman C, Chui CS, Kutcher G, et al. Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate. Int J Radiat Oncol Biol Phys,1997,39(4) : 863-873.
-
3Agazaryan N, Salberg TD, DeMarco JJ. Patient specific quality assurance for the delivery of intensity modulated radiotherapy. J Applied Clinical Med Phys, 2003,4(1) :40-50.
-
4Zhu XR, Jursinic PA, Grimm DF, et al. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys, 2002, 29 (8) :1687-1692.
-
5Childress NL, Dong L, Rosen II. Rapid radiographic film calibration for IMRT verification using automated MLC fields. Meal Phys,2002,29(10) :2384-2390.
-
6Ju SG, Ahn YC, Huh SJ, et al. Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation. Med Phys,2002, 29(3) :351-355.
-
7Dogan N, Leybovich LB, Sethi A. comparative evaluation of Kodak EDB2 and XV2 films for verification of intensity modulated radiation therapy. Phys Med Biol, 2002,47(22) :4121-4130.
-
8Low DA, Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys,2003,30(9) :2455-2464.
-
9Low DA, Harms WB,Mutic S, et al. A technique for the quantitative evaluation of dose distributions. Med Phys, 1998,25(5):656-661.
-
10邓小武,黄劭敏,钟宁山,卢泰祥.调强放射治疗的物理剂量验证[J].癌症,2001,20(10):1092-1094. 被引量:60
共引文献5
-
1李勤,李光俊,韩军,孙长庚.调强验证中胶片刻度方法的研究[J].中华放射肿瘤学杂志,2007,16(5):384-385. 被引量:6
-
2姜瑞瑶,熊霏,黄国锋,曹征,李兆斌,傅深.影响调强放疗绝对剂量的主要因素及应对措施[J].中国医学物理学杂志,2008,25(5):798-800. 被引量:3
-
3何方方,徐晓,赵路军,王克强,冒苏.放疗中呼吸运动对不同形状射野剂量分布的影响[J].中华放射医学与防护杂志,2009,29(3):309-313.
-
4时勇,张芬,张开贤,李成建,张敏.利用二维电离室矩阵进行调强放疗计划剂量验证的探讨[J].中国医疗设备,2014,29(9):120-121. 被引量:8
-
5张孝勇.调强放疗剂量验证影响因素分析[J].基层医学论坛,2015,19(16):2210-2211.
-
1谢秋萍,陈启明.产房消毒质量分析与改进[J].海峡预防医学杂志,1998,4(1):49-49.
-
2皮巧红.护理纠纷和投诉原因分析与改进措施[J].山东医药,2009,49(24):117-118. 被引量:3
-
3李欢,杨蓉.鼻饲管位置验证方法研究进展[J].护理研究(中旬版),2007,21(10):2638-2640. 被引量:2
-
4缪继东,姜萍.宫颈癌放疗后盆腔正常组织的早期MRI变化[J].医学影像学杂志,2014,24(6):1011-1013. 被引量:2
-
5周传銮,李小利.新生儿胃管置入成功三种验证方法可靠性探讨[J].齐鲁护理杂志(下半月刊)(外科护理),2008,14(11):15-15. 被引量:1
-
6王薏,柳文清.介绍一种验证胃管的方法[J].齐鲁护理杂志,2005,11(3):220-220. 被引量:2
-
7王玉莲.烧伤患者营养支持治疗中的问题分析与改进[J].中华烧伤杂志,2009,25(5):341-342. 被引量:1
-
8符洁颖.护理干预对鼻咽癌调强适形放疗患者口腔黏膜反应的影响[J].现代中西医结合杂志,2014,23(26):2955-2957. 被引量:2
-
9高洁,戴娟.46例鼻咽癌患者调强适形放疗不良反应的护理[J].华北煤炭医学院学报,2011,13(6):814-815. 被引量:6
-
10徐晓霞,郭嬿.护理干预对鼻咽癌调强适形放疗中口腔黏膜反应的影响[J].护士进修杂志,2010,25(18):1672-1673. 被引量:16