期刊文献+

Risk of transmission of carbapenem-resistant Enterobacteriaceae and related “superbugs” during gastrointestinal endoscopy 被引量:27

Risk of transmission of carbapenem-resistant Enterobacteriaceae and related “superbugs” during gastrointestinal endoscopy
下载PDF
导出
摘要 To evaluate the risk of transmission of carbapenem-resistant Enterobacteriaceae(CRE) and their related superbugs during gastrointestinal(GI) endoscopy. Reports of outbreaks linked to GI endoscopes contami-nated with different types of infectious agents, includ-ing CRE and their related superbugs, were reviewed. Published during the past 30 years, both prior to and since CRE's emergence, these reports were obtained by searching the peer-reviewed medical literature(via the United States National Library of Medicine's "MEDLINE" database); the Food and Drug Administration's Manu-facturer and User Facility Device Experience database, or "MAUDE"; and the Internet(via Google's search engine). This review focused on an outbreak of CRE in 2013 following the GI endoscopic procedure known as endoscopic retrograde cholangiopancreatography, or ERCP, performed at "Hospital X" located in the sub-urbs of Chicago(IL; United States). Part of the largest outbreak of CRE in United States history, the infection and colonization of 10 and 28 of this hospital's patients, respectively, received considerable media attention and was also investigated by the Centers for Disease Con-trol and Prevention(CDC), which published a report about this outbreak in Morbidity and Mortality WeeklyReport(MMWR), in 2014. This report, along with the results of an independent inspection of Hospital X's in-fection control practices following this CRE outbreak, were also reviewed. While this article focuses primar-ily on the prevention of transmissions of CRE and their related superbugs in the GI endoscopic setting, some of its discussion and recommendations may also apply to other healthcare settings, to other types of flexible endoscopes, and to other types of transmissible infec-tious agents. This review found that GI endoscopy is an important risk factor for the transmission of CRE and their related superbugs, having been recently as-sociated with patient morbidity and mortality following ERCP. The CDC reported in MMWR that the type of GI endoscope, known as an ERCP endoscope, that Hospi-tal X used to perform ERCP in 2013 on the 38 patients who became infected or colonized with CRE might be particularly challenging to clean and disinfect, because of the complexity of its physical design. If performed in strict accordance with the endoscope manufacturer's labeling, supplemented as needed with professional organizations' published guidelines, however, current practices for reprocessing GI endoscopes, which include high-level disinfection, are reportedly adequate for the prevention of transmission of CRE and their related superbugs. Several recommendations are provided to prevent CRE transmissions in the healthcare setting. CRE transmissions are not limited to contaminated GI endoscopes and also have been linked to other reusable flexible endoscopic instrumentation, including broncho-scopes and cystoscopes. In conclusion, contaminated GI endoscopes, particularly those used during ERCP, have been causally linked to outbreaks of CRE and their related superbugs, with associated patient morbidity and mortality. Thorough reprocessing of these complex reusable instruments is necessary to prevent disease transmission and ensure patient safety during GI endos-copy. Enhanced training and monitoring of reprocessing staffers to verify the proper cleaning and brushing of GI endoscopes, especially the area around, behind andnear the forceps elevator located at the distal end othe ERCP endoscope, are recommended. If the ERCPendoscope features a narrow and exposed channel thathouses a wire connecting the GI endoscope's controhead to this forceps elevator, then this channel's com-plete reprocessing, including its flushing with a deter-gent using a procedure validated for effectiveness, is also emphasized. To evaluate the risk of transmission of carbapenem-resistant Enterobacteriaceae(CRE) and their related superbugs during gastrointestinal(GI) endoscopy. Reports of outbreaks linked to GI endoscopes contami-nated with different types of infectious agents, includ-ing CRE and their related superbugs, were reviewed. Published during the past 30 years, both prior to and since CRE’s emergence, these reports were obtained by searching the peer-reviewed medical literature(via the United States National Library of Medicine’s "MEDLINE" database); the Food and Drug Administration’s Manu-facturer and User Facility Device Experience database, or "MAUDE"; and the Internet(via Google’s search engine). This review focused on an outbreak of CRE in 2013 following the GI endoscopic procedure known as endoscopic retrograde cholangiopancreatography, or ERCP, performed at "Hospital X" located in the sub-urbs of Chicago(IL; United States). Part of the largest outbreak of CRE in United States history, the infection and colonization of 10 and 28 of this hospital’s patients, respectively, received considerable media attention and was also investigated by the Centers for Disease Con-trol and Prevention(CDC), which published a report about this outbreak in Morbidity and Mortality WeeklyReport(MMWR), in 2014. This report, along with the results of an independent inspection of Hospital X’s in-fection control practices following this CRE outbreak, were also reviewed. While this article focuses primar-ily on the prevention of transmissions of CRE and their related superbugs in the GI endoscopic setting, some of its discussion and recommendations may also apply to other healthcare settings, to other types of flexible endoscopes, and to other types of transmissible infec-tious agents. This review found that GI endoscopy is an important risk factor for the transmission of CRE and their related superbugs, having been recently as-sociated with patient morbidity and mortality following ERCP. The CDC reported in MMWR that the type of GI endoscope, known as an ERCP endoscope, that Hospi-tal X used to perform ERCP in 2013 on the 38 patients who became infected or colonized with CRE might be particularly challenging to clean and disinfect, because of the complexity of its physical design. If performed in strict accordance with the endoscope manufacturer’s labeling, supplemented as needed with professional organizations’ published guidelines, however, current practices for reprocessing GI endoscopes, which include high-level disinfection, are reportedly adequate for the prevention of transmission of CRE and their related superbugs. Several recommendations are provided to prevent CRE transmissions in the healthcare setting. CRE transmissions are not limited to contaminated GI endoscopes and also have been linked to other reusable flexible endoscopic instrumentation, including broncho-scopes and cystoscopes. In conclusion, contaminated GI endoscopes, particularly those used during ERCP, have been causally linked to outbreaks of CRE and their related superbugs, with associated patient morbidity and mortality. Thorough reprocessing of these complex reusable instruments is necessary to prevent disease transmission and ensure patient safety during GI endos-copy. Enhanced training and monitoring of reprocessing staffers to verify the proper cleaning and brushing of GI endoscopes, especially the area around, behind andnear the forceps elevator located at the distal end othe ERCP endoscope, are recommended. If the ERCPendoscope features a narrow and exposed channel thathouses a wire connecting the GI endoscope’s controhead to this forceps elevator, then this channel’s com-plete reprocessing, including its flushing with a deter-gent using a procedure validated for effectiveness, is also emphasized.
出处 《World Journal of Gastrointestinal Endoscopy》 CAS 2014年第10期457-474,共18页 世界胃肠内镜杂志(英文版)(电子版)
基金 Supported by An educational grant provided by FUJIFILM Medical Systems,USA,Inc.,Endoscopy Division(Wayne,NJ United States)
关键词 Endoscopy Gastrointestinal Carbapenemresistant ENTEROBACTERIACEAE Cross infection Disease outbreaks HEALTHCARE-ASSOCIATED INFECTIONS RISK assessment Disinfection Sterilization Anti-bacterial agents Bacterial INFECTIONS CARBAPENEMS Betalactams Endoscopy Gastrointestinal Carbapenem-resistant Enterobacteriaceae Cross infection Disease outbreaks Healthcare-associated infections Risk assessment Disinfection Sterilization Anti-bacterial agents Bacterial infections Carbapenems Beta-lactams
  • 相关文献

参考文献21

  • 1Douglas B Nelson,Lawrence F Muscarella.Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy[J].World Journal of Gastroenterology,2006,12(25):3953-3964. 被引量:19
  • 2Tom Deas,Lisa Sinsel.Ensuring Patient Safety and Optimizing Efficiency During Gastrointestinal Endoscopy[J]. AORN Journal . 2014
  • 3N. Akyüz,M. Keskin,N. Akyolcu,?. ?avdar,A. ?zba?,T. Ayo?lu,E. Bal?k,T. Bulut.How and how much do endoscopy professionals protect themselves against infection?[J]. International Journal of Surgery . 2014
  • 4P. Gastmeier,R.-P. Vonberg.Klebsiella spp. in endoscopy-associated infections: we may only be seeing the tip of the iceberg[J]. Infection . 2014 (1)
  • 5C.-L. Chang,L.-H. Su,C.-M. Lu,F.-T. Tai,Y.-C. Huang,K.-K. Chang.Outbreak of ertapenem-resistant Enterobacter cloacae urinary tract infections due to a contaminated ureteroscope[J]. Journal of Hospital Infection . 2013
  • 6Sally F. Alrabaa,Phuong Nguyen,Roger Sanderson,Aliyah Baluch,Ramon L. Sandin,Danashree Kelker,Chaitanya Karlapalem,Peggy Thompson,Kay Sams,Stacy Martin,Jose Montero,John N. Greene.Early identification and control of carbapenemase-producing Klebsiella pneumoniae , originating from contaminated endoscopic equipment[J]. AJIC: American Journal of Infection Control . 2013 (6)
  • 7Alexandra M. Dirlam Langlay,Cori L. Ofstead,Natalie J. Mueller,Pritish K. Tosh,Todd H. Baron,Harry P. Wetzler.Reported Gastrointestinal Endoscope Reprocessing Lapses: The Tip of the Iceberg[J]. AJIC: American Journal of Infection Control . 2013
  • 8Jacob, Jesse T,Klein, Eili,Laxminarayan, Ramanan,Beldavs, Zintars,Lynfield, Ruth,Kallen, Alexander J,Ricks, Philip,Edwards, Jonathan,Srinivasan, Arjun,Fridkin, Scott,Rasheed, J Kamile,Lonsway, David,Bulens, Sandie,Herrera, Rosa,McDonald, L Clifford,Patel, Jean,Limbago, Brandi,Bell, Michael,Cardo, Denise.Vital Signs: Carbapenem-Resistant Enterobacteriaceae[J]. MMWR. Morbidity and Mortality Weekly Report . 2013 (9)
  • 9Vincent S.W. Koo,Patricia O’Neill,Andrew Elves.Multidrug‐resistant NDM‐1 Klebsiella outbreak and infection control in endoscopic urology[J]. BJU International . 2012 (11c)
  • 10Minor outbreak of extended-spectrum β-lactamase-producing Klebsiella pneumoniae in an intensive care unit due to a contaminated sink[J]. Journal of Hospital Infection . 2012 (2)

二级参考文献165

  • 1[1]Nelson DB.Infectious disease complications of GI endoscopy:part Ⅱ,exogenous infections.Gastrointest Endosc 2003; 57:695-711
  • 2[2]Seeff LC,Manninen DL,Dong FB,Chattopadhyay SK,Nadel MR,Tangka FKL,Molinari NA.Is there endoscopic capacity to provide colorectal cancer screening to the unscreened population in the United States? Gastroenterology 2004; 127:1661-1669
  • 3[3]Lieberman DA,De Garmo P,Fleischer D,Eisen GM,Helfand M.Patterns of endoscopy use in the United States.Gastroenterology 2000; 118:619-624
  • 4[4]Owings MF,Kozak LJ.Ambulatory and inpatient procedures in the United States,1996.Vital Health Statistics 1998; 13:1-119
  • 5[5]Tennenbaum R,Colardelle P,Chochon M,Maisonneuve P,Jean F,Andrieu J.Hepatitis C after retrograde cholangiography.Gastroenterol Clin Biol 1993; 17:763-764
  • 6[154]Sorin M,Segal-Maurer S,Mariano N,Urban C,Combest A,Rahal JJ.Nosocomial transmission of imipenem-resistant Pseudomonas aeruginosa following bronchoscopy associated with improper connection to the Steris System 1 processor.Infect Control Hosp Epidemiol2001; 22:409-413
  • 7[155]Srinivasan A.Epidemiology and Prevention of Infections Related to Endoscopy.Curr Infect Dis Rep 2003; 5:467-472
  • 8[156]Alfa MJ,Olson N,DeGagne P,Jackson M.A survey of reprocessing methods,residual viable bioburden,and soil levels in patient-ready endoscopic retrograde choliangiopanc reatography duodenoscopes used in Canadian centers.Infect Control Hosp Epidemiol2002; 23:198-206
  • 9[157]Widell A,Christensson B,Wiebe T,Schalen C,Hansson HB,Allander T,Persson MA.Epidemiologic and molecular investigation of outbreaks of hepatitis C virus infection on a pediatric oncology service.Ann In tern Med 1999; 130:130-134
  • 10[158]Bruguera M,Saiz JC,Franco S,Gimenez-Barcons M,Sanchez-Tapias JM,Fabregas S,Vega R,Camps N,Dominguez A,Salleras L.Outbreak of nosocomial hepatitis C virus infection resolved by genetic analysis of HCV RNA.J Clin Microbiol 2002; 40:4363-4366

共引文献18

同被引文献174

引证文献27

二级引证文献224

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部