Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines 被引量:7

Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines
下载PDF
导出
摘要 AIM:To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups.METHODS:This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX(transversal, group 1) or Infiniti OZil IP(torsional, group 2) machine.RESULTS:The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3(2-4) in the first group and2(2-4) in the second group(P =0.265). Both groups had similar phacoemulsification needle times(group 1: 60.63±36 s; group 2: 55.98±30 s; P =0.789). The percentage of endothelial cell loss 30 d after surgery ranged from 3% to15% with a median of 7% in group 1, and from 2% to13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups(P =0.407). Hexagonality(P =0.794) and the coefficient of variation(CV; P =0.142) did not differ significantly between the groups before and 30 d after surgery. Asignificant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade(group1: P 【0.001; group 2: P 【0.001) and between the endothelial cell loss and average phacoemulsification power(group 1: P =0.007; group 2: P =0.008).CONCLUSION:Both of these machines were efficient,with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power. AIM:To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups.METHODS:This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX(transversal, group 1) or Infiniti OZil IP(torsional, group 2) machine.RESULTS:The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3(2-4) in the first group and2(2-4) in the second group(P =0.265). Both groups had similar phacoemulsification needle times(group 1: 60.63±36 s; group 2: 55.98±30 s; P =0.789). The percentage of endothelial cell loss 30 d after surgery ranged from 3% to15% with a median of 7% in group 1, and from 2% to13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups(P =0.407). Hexagonality(P =0.794) and the coefficient of variation(CV; P =0.142) did not differ significantly between the groups before and 30 d after surgery. Asignificant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade(group1: P <0.001; group 2: P <0.001) and between the endothelial cell loss and average phacoemulsification power(group 1: P =0.007; group 2: P =0.008).CONCLUSION:Both of these machines were efficient,with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第5期822-827,共6页 国际眼科杂志(英文版)
关键词 endothelial cell changes TRANSVERSAL torsional PHACOEMULSIFICATION endothelial cell changes transversal torsional phacoemulsification
  • 相关文献

参考文献15

  • 1William J. Fishkind.The phaco machine: analysing new technology[J]. Current Opinion in Ophthalmology . 2013 (1)
  • 2Maged Maher Salib Roshdy,Assaf.Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision[J]. Clinical Ophthalmology . 2013 (default)
  • 3Daniele Tognetto,Paolo Cecchini,Pia Leon,Marta Di Nicola,Giuseppe Ravalico.Stroke dynamics and frequency of 3 phacoemulsification machines[J]. Journal of Cataract & Refractive Surgery . 2012 (2)
  • 4Mohamed Mahdy,Hafez,Mohammed,Bhatia,Eid.Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery[J]. Clinical Ophthalmology . 2012 (default)
  • 5Ken Hayashi,Motoaki Yoshida,Shin-ichi Manabe,Akira Hirata.Cataract surgery in eyes with low corneal endothelial cell density[J]. Journal of Cataract & Refractive Surgery . 2011 (8)
  • 6Panos G. Christakis,Rosa M. Braga-Mele.Intraoperative performance and postoperative outcome comparison of longitudinal, torsional, and transversal phacoemulsification machines[J]. Journal of Cataract & Refractive Surgery . 2011 (2)
  • 7Bokkwan Jun,John P. Berdahl,Terry Kim.Thermal study of longitudinal and torsional ultrasound phacoemulsification[J]. Journal of Cataract & Refractive Surgery . 2010 (5)
  • 8Joseph S. Schmutz,Randall J. Olson.Thermal Comparison of Infiniti OZil and Signature Ellips Phacoemulsification Systems[J]. American Journal of Ophthalmology . 2010 (5)
  • 9Anna Reuschel,Holger Bogatsch,Thomas Barth,Renate Wiedemann.Comparison of endothelial changes and power settings between torsional and longitudinal phacoemulsification[J]. Journal of Cataract & Refractive Surgery . 2010 (11)
  • 10Marek R?kas,Robert Montés-Micó,Karolina Krix-Jachym,Adam Klu?,Andrzej Stankiewicz,Teresa Ferrer-Blasco.Comparison of torsional and longitudinal modes using phacoemulsification parameters[J]. Journal of Cataract & Refractive Surgery . 2009 (10)

共引文献1

同被引文献25

引证文献7

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部