摘要 详细介绍了6种评价同轴电缆屏蔽性能的测量方法,并对各种方法的优缺点进行了比较,为线缆屏蔽性能的实际测试工作提供了参考和依据。 In order to provide the references and experiences for practical work,six different measurement methods for shielding effectiveness of coaxial cable have been described. The advantages and disadvantages of these methods are also compared and discussed here.
作者 张莉
出处 《电线电缆》 2014年第6期21-23,41,共4页 Wire & Cable
关键词 同轴电缆 屏蔽衰减 特性阻抗 coaxial cable screening attenuation characteristic impedance
  • 相关文献

参考文献6

二级参考文献21

  • 1朱荣华,李谦若.表面转移阻抗的测量——三同轴方法[J].光纤与电缆及其应用技术,2005(4):8-11. 被引量:13
  • 2方耿,蒋全兴,周忠元.功率吸收钳法测量射频同轴电缆屏蔽效能[J].安全与电磁兼容,2006(1):12-14. 被引量:3
  • 3戴燕飞,邵武.连接器和电缆电磁屏蔽效果的测试方法[J].机电元件,2006,26(3):37-40. 被引量:6
  • 4International Electrotechnical Commission. IEC/TR 621534-6 2006 Metallic communication cable test methods, part 4 - 6 : electromagnetic compatibility ( EMC ) -surface transfer impedance-line injection method [ S ]. Geneva: International Electrotechnical Commission, 2006.
  • 5European Committee for Electrotechnical Standardization. EN50289-1-6 2002 Communication cables-specifications for test methods-part 1-6 : electrical test methodselectromagnetic performance [ S ]. London : British Standard Institution, 2002.
  • 6Weston D A, MeDougall K. Conduit measured transfer impedance and shielding effectiveness [ EB/OL ]. (2007-02-05) [ 2009-08-01 ]. http://www, emcconsultinginc, com/docs/conduitse. PDF.
  • 7Taghivand M. Correlation between shielding effectiveness and transfer impedance of shielded cable [ C ] //International Symposium on EMC. Santa Clara, CA, USA, 2004 : 942 - 945.
  • 8Ryser H. Uncertainty contributions to the clamp factor CF of the absorbing clamp[ C ]//18th International Zurich Symposium on Electromagnetic Compatibility. Zurich, Switzerland, 2007:385 - 388.
  • 9Carobbi C, Cati M, Panconi C. Defining and assessing the uncertainty contributions in the line-injection measurements of transfer impedance [ C ]//International Symposium on EMC. Detroit, USA, 2008 ( 1 ) : 513 - 518.
  • 10MUELLER J. Cable shielding test methods: a comparison of different test methods[C]//Proceedings of IEEE International Symposium on Electromagnetic Compatibility. [S. l.] : IEEE Press, 2007 : 1-6.

共引文献18

同被引文献9

引证文献5

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部