摘要 目的 比较锁骨下静脉上位置管与颈内静脉置管建立临时性血液透析通路的优缺点。方法 采用回顾性对照研究 ,98例急需血液透析患者先后采用锁骨下静脉上位置管 6 8例 ,颈内静脉置管 30例。观察两种插管途经的穿刺成功率、完成插管时间、导管留置时间、导管相关并发症、血流量及Kt/V值等。结果 锁骨下静脉上位穿刺成功率 94 .1% ,显著高于颈内静脉 80 .0 % (P <0 .0 1) ,完成插管时间亦优于颈内静脉 (P <0 .0 5 ) ;锁骨下静脉上位插管的留置时间明显长于颈内静脉插管 (P <0 .0 5 ) ,锁骨下静脉上位置管的血流量不足、感染及导管堵塞发生率均低于颈内静脉置管 (P <0 .0 5 ) ,两部位插管的Kt/V值无显著性差异 (P >0 .0 5 )。结论 相对而言 。 objective To compare the advantages and disad vantages of epistatic subclavian vein catheterization (ESVC) with that of internal jugular vein catheterization (IJVC) in hemodialysis. Methods Sixty-eight ESV C and 30 IJVC were performed in 98 hemodialysis patients rate of puncture success, catheterization time, the catheters' survival life, complications, blood flow and Kt/V were observed retrospectively. Results Rate of puncture success of ESVC was significantly higher than that of IJVC (94.1% vs 80% respectively P<0.05) and catheterization time of ESVC was shorter obviously than that of IJVC (P<0.05); The survival life of ESVC was longer significantly than that of IJVC (P<0.05) and a lower incidence of infection, inadequate blood flow and obstruction were also found; Kt/V of ESVC and IJVE was of no significant difference (P>0.05).Conclusions ESVC is relatively an ideal temporary blood access for hemodialysis.
出处 《中国血液净化》 2004年第6期316-318,共3页 Chinese Journal of Blood Purification
关键词 锁骨下静脉 颈内静脉 双腔导管 血液透析 Subclavian vein Internal jugular vein Dual-lumen catheter Hemodialysis
  • 相关文献

参考文献7

  • 1[1]Parsa MH,Tabord F.Central venous access in critically ill patients in the emergence department.Emery Med Clin North Am,1986,4 (3):709-744
  • 2[2]Jones CE.Efficacy of the supraclaricular route of temporary hemodialysis access.South Med J,1992,85(8):725
  • 3赵宗河,张新,姜埃利.锁骨下静脉上位置管术在血液透析中的应用[J].天津医药,2000,28(3):181-183. 被引量:2
  • 4[4]Buur T,Will EJ.Hemodialysis recirculation measured using a femoral artery sample.Nephrol Dial Transplant,1994,9(4):395-398
  • 5[5]Daugirdas JT.Second generation logarithmic estimates of single-pool variable volume Kt/V:an analysis of error.J Am Soc Nephrol,1993,4(6):1199-1204
  • 6[6]Dupent D,Moriniere P,Pourchez T,et al.Long term development of Permcath Quinton catheters used as a vasular access route for extra-renal detoxificat ion.Nephrdogic,1994,15(7):105-109
  • 7[7]Shusterman NH,Kloss K,Mullen JL.Successful use of double-umen,silicon rubber catheters for permanent hemodialysis access.Kidney Int,1989,35(8):887-892