期刊文献+

高氯废水中COD_(Cr)测定方法的探讨 被引量:2

Study on the Determination of COD_(Cr) in Wastewater with High Chlorine
下载PDF
导出
摘要 CODCr作为评价有机物污染的重要指标,在测定中氯离子是影响结果准确性的重要因素.研究了完全氧化法消除Cl-干扰的可行性,测定了K2Cr2O7浓度对Cl-对应CODCr的影响,绘制了完全氧化法的标准曲线;研究了ρ(Cl-)对水样CODCr结果的影响.结果表明完全氧化法适用于高氯废水中CODCr的测定. By COD_(Cr) as organic pollutants indexes,chlorine ion in aqueous-solution sample is the important interfering factor that can affect the accuracy of the determinative result.Based on the chemical experimentation the feasibility of eliminating the interference of chlorine ion was discussed by absolute oxidation,the COD_(Cr) responding to the chlorine ion in a series of samples containing different K_2Cr_2O_7 concentrations,and made the standard curve of absolutely oxidation,and deliberating COD_(Cr) in actual samples containing varied chlorine ion concentrations.Consequence has shown that absolute oxidation is fit in determining COD_(Cr) in the organic pollutant high-chlorine water.
出处 《河北师范大学学报(自然科学版)》 CAS 2004年第4期393-395,共3页 Journal of Hebei Normal University:Natural Science
基金 河北省科学技术攻关项目(01276727D)
关键词 高氯废水 CODCR 测定方法 氯离子 水质监测 chemical oxygen demand  chlorine ion  determination