摘要
本文以我国动力行业四十几年来的电站锅炉设计、运行经验为基础,通过对国内二十几个电厂运行情况良好的锅炉机组实际运行数据理论分析及回归整理,系统地建立了炉膛截面热负荷(?)、上一次风口中心线至屏底的高度L_(?)的计算方法,并给出了回归计算公式及相应的图表.
The paper presents the calculation methods of the furnacecross—section heat release rate (?) and the height L(?) from thecenter line of primary air port to platen bottom in accordanceto the experiences in design and operation of utility boiler formore than forty years in domestic power industry and the the-oretical and regressive analysis for the actual operating datawhich is gained by the stable operation boiler for more thantwenty units at home.The formulas of regressive calculationand their relative figures and tables are given.
出处
《电站系统工程》
1993年第3期51-57,共7页
Power System Engineering