摘要
详细介绍了丹江电厂三号发电机改造前后的通风、温升试验过程及对试验结果的分析 ,可为现场同类试验提供参考。
The paper described the processes of the ventilation and temperature-rise test in the NO.3 hydro generator of Danjiangkou power plant in detail and the test data were analyzed. It is of reference value for the site test of the same kind.
出处
《四川电力技术》
2004年第3期41-43,共3页
Sichuan Electric Power Technology
关键词
水轮发电机
通风
温升
损耗
hydro generator
ventilation
temperature-rise
loss