摘要
广州抽水蓄能电厂在近几年的水库运行调度中,发现了一些值得探讨的问题。本文主要介绍了广州抽水蓄能电厂上下库调度方案和实际运行情况,分析了问题产生的原因,提出了相应的解决方案,并对抽水蓄能电站水库规划设计进行了一些探讨,以供同类型电站设计时参考。
In the recent years,some problems appeared during the reservoir regulation of Guangzhou pumped storage power station.This article mainly introduced the scheme and implementation of the upper and lower reservoirs' regulation,analyzed the reasons why the problems appeared. Some resolvents were put forword,the layout and design of the reservoirs of pumped storage power station were discussed.
出处
《大坝与安全》
2004年第3期22-25,共4页
Dam & Safety
关键词
广州蓄能电厂
水库调度
最佳运行总库容
机组最大可调度库容
Guangzhou pumped storage power station,reservoir regulation,the best total storage of the upper and lower reservoir,the largest storage capacity of reservoirs the units available