超声波技术检测乳化液浓度的机理与实验 被引量:8

Study of Inspecting Emulslon Concentration with Ultrasonic Technique
下载PDF
导出
摘要 通过仿真技术的理论和人工配比的实验 ,对超声波技术检测乳化液浓度的原理进行了研究 ,结果表明 ,信号稳定性和重复性良好 ,测试时间短 ,测试误差在允许的范围内 ,其技术可行。 In the paper description is made of the mechanism for inspecting emulsion concentration with ultrasonic technique, through simulation and artifical experiments. The results show signals are sound in both stability and repeatability. Moreover, the inspection period is much shorter than that of the old method, and inspection error is within the limit permitted. The technique proves feasible.
出处 《武汉工程职业技术学院学报》 2004年第2期8-11,7,共5页 Journal of Wuhan Engineering Institute
关键词 超声波 乳化液 浓度 ultrasonic emulsion concentration
  • 相关文献

参考文献4

二级参考文献11

  • 1刘镇清.乙醇—水混合液的声速与浓度关系及其热力学特征[J].同济大学学报(自然科学版),1996,24(2):183-188. 被引量:7
  • 2宋心元(译).水和废水标准检验法[M].中国建筑工业出版社,1993..
  • 3岳舜琳.水的浊度测定[J].上海城镇供水,1989,.
  • 4[1]M.A. Ali, K. Mitwally, and Samir A. Aahmed. Reflectance of an absorbing medium for incident light of arbitrary polarization:correlation between the os, cillatory behavior and the complexεplane. Applied Optics, 1990, 29(31):4633-4637.
  • 5[2]RadislavA. Potyrailo, VincentP. Ruddy, andGaryM. Hieftje. Kramers-Kronig analysis of molecular evanescent-wave absorption spectra obtained by Multimode step-index optical fibers. Applied Optics, 1996, 35(21):4102-4110.
  • 6[3]Larald. Gnewuch and Hagen Renner. Mode-independent attenuation on Evanescent-field sensors. Applied Optics, 1995, 34(9): 1473-1482.
  • 7[4]Rabah Belali and Jean-Marie Vigoureux. Dispersion effects on in-fraredSpectry in attenuated total reflection. J. Opt. Soc. Am. B, 1995,12: 2377-2381.
  • 8魏墨盦,朱士明,孙长俊.超声波声速仪及其在化工分析上的应用[J]同济大学学报,1979(01).
  • 9罗南星.测量误差及数据处理[M]计量出版社,1984.
  • 10宋启敏,陆明刚.散射光式浊度测量的范围和非线性研究[J].上海大学学报(自然科学版),1997,3(5):564-569. 被引量:17