摘要
U_3O_3用HNO_3溶解,用TBP萃淋树脂分离铀,水溶液用HClO_4蒸干,残渣溶于10ml、pH=6.1的0.1mol/L EDTA、lmol/L的NaAc溶液中,加入1%铜铁试剂0.5ml,于-0.6V~-1.1V的电位范围内用方波伏安法测定钛。标准偏差约为5%,最低检出限为0.5ng/ml。
The U3O8 sample is dissolved in nitric acid and uranium is removed by TBP levetrel resin. The aqueous solution is evaporated to dryness with perchloric acid. The residue is dissolved in 10 ml of 0. 1 mol/L EDTA-1 mol/L NaAc at pH 6. 1±0. 1.Then 0. 5 ml of 1% cupferron is added. The titanium is determined by square wave voltammetry between -0. 60--1. 10 V(vs. Ag/AgCl). This method is accurate and precise. The detection limit is 0. 5 ng Ti/ml.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1993年第9期1049-1051,共3页
Chinese Journal of Analytical Chemistry
关键词
方波伏安法
八氧化三铀
钛
Square wave voltammetry,Triuranium octaoxide,Titanium.