皮质骨厚度对支抗种植体-骨界面应力分布的影响 被引量:11

The effect of cortical bone thickness on stress distribution of implant-bone interface
下载PDF
导出
摘要 目的 :研究皮质骨厚度改变对支抗种植体 -骨界面应力分布的影响 ,供临床参考。方法 :用三维有限元方法 ,对分别种植于皮质骨厚度为0.5mm、1.0mm、2.0mm颌骨模型中的种植体施加150g近远中方向的载荷 ,分析支抗种植体 -骨界面应力分布情况。结果 :三者种植体颈部的Von -Mises应力值分别为0.6040MPa、0.5330MPa、0.5380MPa ;位移值分别为0.2110μm、0.1630μm、0.1250μm。结论 :皮质骨在一定厚度内 ,植入体颈部皮质骨越薄 ,骨界面应力值就越大。但皮质骨超过一定厚度后 ,骨界面应力并不随其厚度的增加而做相应递减。皮质骨的厚度与界面骨的位移成反比。 Objective:To investigate the effect of different cortical bone thickness on stress distribution of implant-bone interface,thus to provide reference in clinics.Method:Three-dimension finite element analysis method was used to analyze the stress distribution on implant-bone interface,and a force load of150g was applied mesio-distally on the implant embedded in three jaw models with three different cortical bone thickness,0.5mm,1.0mm and2.0mm respectively.Results:In three jaw models,the values of Von-Mises stress on implant neck were0.6040MPa,0.5330MPa,and0.5380MPa respectively,the values of displacement were0.2110μm,0.1630μm and0.1250μm respectively.Conclusion:In certain range of thickness,the thinner the cortical bone around the implantneck,the greater the stress on the bone interface.However,when the thick-ness of cortical bone exceeds some extent,the stress on bone interface does not decrease with the increasing of cortical bone thickness.The thickness of cortical bone is inversely proportional to the displacement of interface bone.
出处 《中国口腔种植学杂志》 2004年第2期54-57,共4页 Chinese Journal of Oral Implantology
基金 广东省医学科学技术研究基金资助项目。项目编号 :A2002944
关键词 支抗种植体 三维有限元 支抗种植体-骨界面 皮质骨 anchorage implant three-dimension finite element implant-bone interface cortical bone
  • 相关文献

参考文献12

  • 1Papavasilion G, Kamposiora P, Stenhen C et al. Three- dimensional finite element analysis of stress- distribution around single tooth implants as a function of bone support, prosthesis type, and loading during function. J Prosthet Dent, 1996, 76(6): 633~
  • 2Lozada JL, Abbate MF, Pissarello FA, et al. Comparative three- dimensional analysis of two finite- element endosseous implant designs. J Oral Implantol, 1994, 20(4): 315- 321
  • 3Lundgrens. Surgical considerations for endosseous implants in the craniofacial region: a 3- year report.Int J Oral Maxillofac Surg, 1993, 22(2): 272- 277
  • 4Clelland NL, Lee JK, Gilat A et al. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J Prosthodont, 1993, 2(3):183- 189
  • 5Victor BE. Craniofacial osseointegrated implant- induced strain distribution: a numerical study. Int J Oral Maxillofac Implants, 1997, 12(2): 200-210
  • 6Holmes DC, Loftus JT. Influnence of bone quality on stress distribution for endosseous implants. Oral Implant, 1997, 23(3): 104-111
  • 7Kitoh M, Suetsugu T, Murakamir, et al. The stress distribution of the hydroxyapatite implant under the vertical load by the two- dimensional finite element method.J Oral Implant, 1988, 14(1): 65- 71
  • 8Cook SD, Weinstein AM, Klawitter J. A three- dimensional finite element analysis of porous rooted Co- Cr- Mo alloy dental implants. J Dent Res, 1982, 61(1):25- 29
  • 9Borchers L, Reichart P. Three- dimensional stress distribution around dental implants in different stage of interface development. J Dent Res, 1983, 62(2):155- 159
  • 10藤原道夫.日本人有齿下颚骨の内部构造にすゐ研究[J].齿科学报,1989,89(3):561-584.

同被引文献179

引证文献11

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部