摘要
本文提出一种新型的离子色谱方法,采用恒电流电场代替机械泵输送离子,研制出体积小、重量轻、成本低、易操作的电迁移微离子色谱仪,并检测了几种常见的阴离子,Cl^-、Br^-、NO_2^-的检测极限为10^(-11)~10^(-12)mol,峰高和保留时间重现性相对标准偏差均<3%,进样量与峰高的线性关系良好。
A new system for ion chromatography is presented. In this system, the pump was displaced by a constant-current power source. The electrical migration of micro-ion chromatography is simpler in structure and cheaper in cost. The results show that the detection limit for Cl- , Br- ,NO2- is 10-11-10-12 mol/L. and the relative standard deviation of reproducibilitiy for peak height and retention time is less than 3%. The peak height is linear to the injection quantity.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1993年第3期352-356,共5页
Chinese Journal of Analytical Chemistry
关键词
电迁移
离子色谱
离子交换树脂
Electrical migration, Ion chromatography. Ion exchange resin.