摘要 本文报道了流动注射在线柱预富集ICP光谱测定痕量金属的方法,以meso-四(4-磺基苯)卟啉为柱前衍生试剂,硅胶作固定相和盐酸作洗脱液,对痕量金属离子Cu、Mn、Ni、Fe、Pb、Cd进行在线预富集检测。在给定实验条件下,方法的富集倍数为9.3~11.3,检出限和测定的相对标准偏差(n=6)分别在0.32~26.8ng/ml和1.3%~3.0%范围内。方法用于小牛肝和西红柿叶样品分析,结果与参考值吻合。 A method for on-line column preconcentration and determination of trace amounts of copper, manganese, nickel, iron, lead and cadmium by folw injection-ICP-AES has been developed. meso-tetrakis-(4-sulfophenyl)porphyrin is used as a reagent for pre-column derivation, silica gel as solid phase and hydrochloric acid as eluent. Under the optimum condition, the enrichment factor is in the range of 9. 3-11. 3, the detection limit of 0.32-26.8 ng/ml and the relative standard deviation of 1.3-3.0%(n = 6) are obtained. It has been applied to the determination of NBS standard samples of bovine liver and tomato leaves with satisfactory results.
机构地区 武汉大学化学系
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1993年第12期1410-1413,共4页 Chinese Journal of Analytical Chemistry
关键词 流动注射 等离子体光谱 卟啉 Flow injection analysis Plasma spectrometry Porphyrin Copper Manganese Nickel Iron Lead Cadminum Preconcentration.