期刊文献+

Experimental Investigation of Spray Evaporation in Turbulent Flow in Countercurrent Humidifier

Experimental Investigation of Spray Evaporation in Turbulent Flow in Countercurrent Humidifier
下载PDF
导出
摘要 The process in the countercurrent humidifier of HAT cycle involves the evaporation of atomized liquids in a turbulent environment. To allow an optimization of such process and provide data for the validation of numerical calculation, the spray evaporation in a countercurrent air stream was studied experimentally. Measurements were taken for different flow parameters, such as airflow rate and liquid flow rate in order to provide reliable data. Phase-Doppler anemometry (PDA) was applied to obtain the spatial change of the droplet size spectrum in the flow field and to measure droplet size-velocity correlations. These local measured profiles of droplet mean velocities, velocity fluctuations and droplet mean diameters were obtained by averaging over all droplet size classes. Moreover, DualPDA signal processing allows accurate determination of the droplet mass flux and local concentration, from which the global evaporation rates could also be determined. These local temperature profiles were measured using the thermocouple and acquired by data acquisition system based on virtual instrument (VI) technology. The process in the countercurrent humidifier of HAT cycle involves the evaporation of atomized liquids in a turbulent environment. To allow an optimization of such process and provide data for the validation of numerical calculation, the spray evaporation in a countercurrent air stream was studied experimentally. Measurements were taken for different flow parameters, such as airflow rate and liquid flow rate in order to provide reliable data. Phase-Doppler anemometry (PDA) was applied to obtain the spatial change of the droplet size spectrum in the flow field and to measure droplet size-velocity correlations. These local measured profiles of droplet mean velocities, velocity fluctuations and droplet mean diameters were obtained by averaging over all droplet size classes. Moreover, DualPDA signal processing allows accurate determination of the droplet mass flux and local concentration, from which the global evaporation rates could also be determined. These local temperature profiles were measured using the thermocouple and acquired by data acquisition system based on virtual instrument (VI) technology.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2004年第1期19-25,共7页 上海交通大学学报(英文版)
基金 973 Key Develop Projectof the Ministry ofScience and Technology of China (No.G19990 2 2 3 0 3 )
关键词 spray phase-Doppler anemometer (PDA) turbulence EVAPORATION droplet velocity droplet size HUMIDIFIER 湍流 多普勒相位风速计 液滴速度 液滴尺寸 增湿器
  • 相关文献

参考文献5

  • 1Sommerfeld M,Qiu H-H.Experimental studies of spray evaporation in turbulent flow[].International Journal.1998
  • 2Byeongil An,Yasuhiro Daisho.Measurement of evaporating process of sprays having different boiling points[].J ASE Review.2000
  • 3Yoshio Higashiyama,Shin’ ichi Tanaka,Toshiyuki Sugimoto,et al.Size distribution of the charged droplets in an axisymmetric shower[].Journal of Electrostatics.1999
  • 4XIAO Yuhan,CAI Ruixian,LIN Runmou.Modeling HAT and thermodynamic evaluation[].Energy Conversion and Management.1997
  • 5McDonell V G,Samuelsen G S.An experimental database for the computational fluid dynamics of reacting and nonreacting methanol sprays[].Journal of Fluids Engineering Transactions of the ASME.1995

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部