期刊文献+

不同强度混凝土梁柱节点承载性能研究 被引量:7

Experimental reseach on interior beam-column joints as the column and beam are constructed with different strength concrete
下载PDF
导出
摘要 为了保证高层建筑混凝土梁柱节点核心区强度和承载性能,研究参考国内外经验数据,提出相应的方法,其中柱采用强度等级较高的混凝土,梁和节点区采用强度等级较低的混凝土,2个试件节点区采用角钢笼加强,并结合现行混凝土规范,论述了4个梁柱节点试件的试验结论,提出了梁柱节点的设计建议。 In order to make the beam-column joints in high-rise buildings have considerable strength and bearing capability,it is put farward that the strength of concrete in the beam-column joints shall be the same with that in the beams and slabs,and in the meantime,the joints shall be reinforced with the cage structure formed with angle bars and gusset plates. The test results of four specimens of reinforced concrete interior beam-column joints are described and analyzed. And the joints of two specimens are strengthened with the cage structure. The design recommendations of beam-column joints are given.
出处 《合肥工业大学学报(自然科学版)》 CAS CSCD 2004年第4期396-400,共5页 Journal of Hefei University of Technology:Natural Science
关键词 不同强度等级混凝土 梁柱中节点 角钢笼 轴心受压 承载性能 different strength concrete interior beam-column joint cage structure formed with angle bars and gusset plates axial-compression
  • 相关文献

参考文献4

二级参考文献15

  • 1.GB50010-2002.混凝土结构设计规范[S].,2002..
  • 2赵鸿铁.组合结构[M].西安:西安建筑科技大学出版社,1989.94-99.
  • 3袁明武,SAP83微机结构分析通用程序,1992年
  • 4杨海元,固体力学数值方法,1991年
  • 5赵西安,钢筋混凝土高层建筑结构设计(第2版),1990年
  • 6团体著者,混凝土结构设计规范.GBJ10-89,1989年
  • 7梁启智,高层建筑结构分析与设计,1983年
  • 8佟景伟,实验应力分析,1983年
  • 9Bianchini A C,Woods R E,Kesler C E.Effect of floor concrete strength on column strength[].ACI Journal.1960
  • 10Gamble W L,Klinar J D.Test of high-strength concrete columns with intervening floor slabs[].Journal of Structural Engineering ASCE.1991