分析了 6 0 0MW机组超临界压力直流锅炉水冷壁水动力特性、给水特性及其对运行操作的要求 ,为确保超临界压力直流锅炉水冷壁的安全运行提供了理论依据。
The hydrodynamic performance and feed-water characteristics, as well as requirements for service operation of the waterPRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS$$$$ XIE Jiang Abstract:The hydrodynamic performance and feed-water characteristics, as well as requirements for service operation of the water[CD*2- system concerning supercritical pressure once-through boiler of 600MW units have been analysed, providing theoritical basis for ensuring water-wall’s safe operation of the said supercritical pressure once-through boiler.