期刊文献+

精密电阻分压器测量误差的频率特性 被引量:1

The Frequency Characteristic of Measuring Error of Precsison Resistance Dividers
下载PDF
导出
摘要 分析了脉动分量和杂散参数对带屏蔽的电阻分压器测量误差的影响,导出了误差与分压器结构参数的关系式,通过模拟计算得到了误差随一些参数的变化曲线,提出了减小误差的措施。结果表明,合理的结构设计能够显著地减小误差。 The effects on the shielded resistance divider of pulse ripple componentand stray parameter have been analysed in this paper. The relation between error and constructional parameters and deduced. Calculation, the relation curves of error with some parameters wereo btained. It was proved that the reasonable construction design can reduce error obviously. Finally, some methods to reduce error were presented.
出处 《高电压技术》 EI CAS CSCD 北大核心 1993年第1期13-17,共5页 High Voltage Engineering
关键词 电阻分压器 测量误差 频率响应 resistance dividers measuring error pulse ripple freguency characteristic
  • 相关文献

参考文献1

二级参考文献2

  • 1赵有斌.直流250kV精密电阻器的研制[J]高电压技术,1988(01).
  • 2赵有斌.在直流高电压测量中减少电晕电流引起误差的措施[J]高压电器,1986(05).

共引文献5

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部