在热设计的基础上,建立了大型高温热管换热器热态实验模型,采用计算机实时检测系统测定了换热器内温度场实际分布状 况。并通过实验结果与模拟计算结果的分析比较,表明目前高温热管换热器设计中存在的问题,为进一步研究奠定基础。
on the basis of the theoretical design, a thermal physical model of the high-temperature heat pipe heat exchanger (HTHPHE) was established. The distribution of the temperature field in the HTHPHE is determined directly by employed the real-time detection system. Moreover, the results of the test and the calculation are analyzed and compared. The result showed that some problems were exited in design HTHPHE so that providing basis for further study
出处
《工业加热》
CAS
2004年第3期23-27,共5页
Industrial Heating
关键词
高温热管
换热器
温度场
热态模拟
high temperature heat pipe
heat exchanger
temperature field
thermal simulation