摘要
针对锦州东港电力有限公司各台机组凝汽器频繁漏泄的原因 ,从铜管材质、沉积物、运行工况、检修操作、铜管保养等方面进行了分析 ,采取相应措施 ,收到了很好的效果 .
The frequent leakage in condensers caused by crrosion at Jinzhou eastern power co.Ltd.were analyzed in terms of materials,sediment,running conditions,overhaul operation,maintenance for the copper pipe etc.The counter-measures were accordingly proposed and the relevant effectivenes is also summed up.
出处
《腐蚀科学与防护技术》
CAS
CSCD
北大核心
2004年第4期256-258,共3页
Corrosion Science and Protection Technology
关键词
凝汽器
铜管
腐蚀
防护
发电厂
condenser
copper alloy
corrosion
protection