期刊文献+

涡流法检测铝硅合金显微组织的误差分析

ERROR ANALYSIS OF MICROSTRUCTURE GRADE OF AL-SI ALLOY BY EDDY CURRENT TESTING
下载PDF
导出
摘要 当采用涡流法检测铝硅合金活塞显微组织级别时,合金的含硅量、变质剂的加入量以及温度变化都将影响分级结果的准确性。分析了由以上因素引起的显微组织的分级误差,确定了含硅量不同时的修正因子,变质剂的加入量以及温度变化时的校核方式,并采用数理统计方法分析了测试的可靠性,最后得出该涡流检测的分级准确率可达99%。 When testing the microstructure grade of piston made of Al-Si alloy with eddy current method, the percentage of Si in the alloy, number of inoculum and enviromental temperature would affect the accuracy of grading. The grading error of microstructure caused by the factors upon were analyzed, the correction factor applied in different percentage of Si, adding number of inoculum and calibration during temperature altering were confirmed, and the reliability of the testing was analyzed by statistics. Results showed that the grading accuracy by eddy current method was upon 99%.
作者 曾辉 曾琪
出处 《无损检测》 2004年第7期372-374,共3页 Nondestructive Testing
关键词 涡流检验 合金 显微组织 分级 误差分析 Eddy current testing Alloy Microstructure Grading Error analysis
  • 相关文献

参考文献3

二级参考文献3

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部