摘要 基于SolarCentaur50燃气轮机简单循环冷热电联产系统,结合工程实例给出了燃气轮机进口空气温度对冷热电联产系统性能的影响。 Based on Solar Centaur 50 gas turbine CCHP(combined cool heat and power) system operated as a simple cycle, influence of inlet air temperature of gas turbine on CCHP performance is given being combined with practical engineering example.
作者 左政 华贲
出处 《煤气与热力》 2004年第7期369-371,共3页 Gas & Heat
基金 国家重点基础研究发展规划项目(G20000263) 广东省科技攻关项目(133-B27380)
关键词 冷热电联产 燃气轮机 进气冷却 CCHP(combined cool heat and power) gas turbine inlet air cooling
  • 相关文献

参考文献3

  • 1Energy Information Administration of U.S. Department of Energy. The Market and Technical Potential for Combined Heat and Power in the Commercial/Institutional Sector[R]. [s. 1.]: Energy Information Administration of U. S. Department of Energy, 2000.
  • 2Mohanty B, Paloso G. Enhancing Gas Turbine Performance by Intake Air Cooling Using an Absorption Chiller[J]. Heat Recovery and CHP, 1995,(15) :41-50.
  • 3You sef S H. Enhancement of Performance of Gas Turbine Engines by Inlet Air Cooling and Cogeneration System[ J ].Applied Thermal Engineering, 1996, (16) :163-172.