本文阐述了镁氯化厂房建筑结构在有腐蚀介质的生产条件下破损情况和原因;并对湿法炼镁氯化厂房在结构上、生产设备布置上和设计、施工、材料使用等方面,提出了应采用的措施、注意事项和一些建议。
This paper gives on exposition to the damage state and cause of the building structure on
the magnesium chlorinated factory building under the condition of production with the
corrodent medium, and also presents some adopted measures, points for attention and sugges-
tions on the structure, arrangement of production equipment, design, construction and
buiding material of the wet-smelting magnesium chlorinated factory building etc.