摘要 为减少GIS/GCB产品运行期间成本,必须改变维护方式,即从设备的定期维护改变到状态维护。介绍了状态检测项目:监视GIS气体(温度、压力、密度及含水量);局部放电监测:断路器机械、电气性能监测。认为这些监测的共用技术都是以传感器信息为基础,要给予充分重视。 In order to reduce the cost in GIS/GCB product operation period,maintenance method must be changed,that is to say from periodical maintenance to be changed to status maintenance.The items of status testing are introduced as:GISgas (temperature,pressure,density and moisture)monitoring; partial discharge monitoring;and monitoring for the circuit-breaker mecha-nism and electrical performance.And it is considered that common techniques for these monitorings are all based on sensor's information,which should be paid to with great attention.
作者 陈振生
出处 《江苏电器》 2004年第4期18-23,共6页
关键词 高压电器 GIS GCB 气体绝缘 电器设备 状态维护 局部放电 温室效应 GIS periodical maintenance status maintenance density temperature partial discharge vibration travel distance