期刊文献+

适用于ppt级元素分析的实验室用超纯水

下载PDF
导出
摘要 本文集中讨论高敏感性、多元素分析仪器电感耦合等离子体 质谱 (ICP MS) ,仔细选择纯水系统的所有部件 ,且其结构是为超微量分析的目的而特别制造的 ,在定量分析中使用这样的水制备系统产生的超纯水 ,能分析低于ppt级的浓度。
出处 《现代仪器》 2004年第4期54-57,15,共5页 Modern Instruments
  • 相关文献

参考文献21

  • 1Jackson K.W., Guoru C. Atomic Absorption, Atomic Emission,and Flame Emission Spectrometry ,Analytical Chemistry, 1996,68(12) :231 ~ 256
  • 2Olesik J.W.Fundamental Research in ICP-OES and ICP-MS,Analytical Chemistry News & Features, 1996
  • 3Hoenig, M.; Cilissen, A. Performances and Practical Applications of Simultaneous Multi-Element Electrothermal Atomic Absorption Spectrometry the Case of the SIMAA 6000, Spectrochimica Acta,PART B, 1997,1715
  • 4Newman, A.Elements of ICP-MS, Analytical Chemistry News & Features, 1996,46 ~ 51
  • 5Hurley, J.P.; Shafer, M.M.; Cowell, S.E.; Overdier, J.T.;Hughes P.E.; Armstrong, D. E. Trace Metal Assessment of Lake Michigan Tributaries Using Low Level Techniques Environmental Science & Technology 1996,30(6):2093 ~ 2098
  • 6Kawabata, K.; Takahshi, H.; Endo, G.; Inoue, Y. Determination of Arsenic Species by Inductively Coupled Plasma Mass Spectrometry with Ion Chromatography Applied Organometallic Chemistry 1994,8:245 ~ 248
  • 7Kishi, Y.; Gomez, J.; Potter, D. The Determination of Impurities in Sulfuric Acid by ICP-MS, HP Application Note, 1995:5964 ~0142
  • 8Yamanaka, K.; Gomez, J.; Kishi, Y.; Potter, D. The Determination of Impurities in Nitric Acid and Hydrofluoric Acid by ICPMS? Hp Application Note, 1995,5964 ~ 0142E
  • 9Woller, A.; Garraud, H.; Martin, F.; Donard, O.F.X.; Fodor,P. Determination of Total Mercury in Sediments by MicrowaveAssisted Digestion-Flow Injection-Inductively Coupled Plasma Mass Spectrometry, Journal of Analytical Atomic Spectrometry 1997,12:53 ~ 56
  • 10Horowitz, A.J.Some Thoughts on Problems Associated With Various Sampling Media for Environmental Monitoring, The Analyst, 1997,122:1193 ~ 1200

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部