期刊文献+

水样中镉镍的两次双波长分光光度法测定 被引量:3

Dual Wavelength Spectrophotometry for Determination of Cadmium and Nickel in Water
下载PDF
导出
摘要 研究采用两次双波长分光光度法 ,一次采用双峰双波长法 ,一次采用系数补偿法同时测定水样中的镉和镍。实验结果表明 ,以 5 Br PADAP为显色剂 ,镉和镍的最大吸收峰分别为 544 .8nm和 559.2nm ,最小吸收峰均为 430nm ;镉镍的线性范围为 1~ 1 6μg/ 2 5mL。此法的灵敏度同单波长法相比有明显的提高 ,应用于合成和电镀水样中的镉镍的测定 ,均得到了满意的结果。 Dual wavelength spectrophotometry is applied for simultaneously determining cadmium and nickel. The spectrophotometry is comprised of two times measurements: first is dual peak/dual wavelength method; second the compensating coefficient method. The results indicate that with 5-Br-PADAP as a developer the greatest absorption peaks for Cd and Ni are 544.8 nm and 559.2 nm respectively, and the linear range: 1 to 16μg/25mL. It is concluded that sensibility is greatly upgraded compared with the conventional single wavelength method.
出处 《环境科学与技术》 CAS CSCD 2004年第5期29-30,共2页 Environmental Science & Technology
关键词 两次双波长分光光度法 双峰双波长法 系数补偿法 5-BR-PADAP dual wavelength spectrophotometry two times compensating coefficient method dual peak/dual wavelength method cadmium nickel 5-Br-PADAP
  • 相关文献

参考文献3

二级参考文献6

  • 1张东卓,分析试验室
  • 2王保宁,分析化学,1988年,16卷,5期,402页
  • 3王淑仁,理化检验.化学分册,1986年,22卷,2期,97页
  • 4杨泉生,分析试验室,1983年,4卷,43页
  • 5王淑仁等.双波长分光光度法[M]山东科学技术出版社,1986.
  • 6倪永年,黄国平,袁安政.多波长K系数法测定混合干扰组分[J].分析化学,1989,17(4):368-371. 被引量:25