期刊文献+

多普勒组织成像技术评价不同阶段左室舒张功能障碍的价值 被引量:1

Value of Doppler tissue imaging in the evaluation of left ventricular diastolic dysfunction at different stages
下载PDF
导出
摘要 目的探讨二尖瓣环前壁、下壁组织多普勒运动速度频谱在评价不同阶段左室舒张功能障碍中的意义。方法采用组织多普勒技术(Dopplertissueimaging,DTI)测定100例不同阶段左室舒张功能障碍患者及30例正常人的二尖瓣环前壁(mitralannu-lar/anteriorwall,MVA/AW)、下壁(mitralannular/inferiorwall,MVA/IW)运动速度频谱,并与其二尖瓣血流频谱(pulsivewave,PW)相比较。结果①弛张功能减阶段,PW-E/A,MVA/AW-E/A及MVA/IW-E/A均降低(P<0.01),MVA/AW-E/A与PW-E/A高于MVA/IW(100%和60%,P<0.01)。②假性正常化阶段,PW-E/A与正常比较,差异无显著意义(P>0.05),MVA/AW-E/A、MVA/IW-E/A降低,差异有显著性意义(P<0.01),且MVA/AW-E/A与PW-E/A符合率底于后者(20%和40%,P<0.01)。③限制性充盈阶段,3组E/A均高于正常差异有显著性意义(P<0.01),但MVA/IW-E/A与PW-E/A符合率明显高于MVA/AW-E/A(89%和22%)。结论多普勒组织成像技术测定二尖瓣环前壁、下壁运动频谱在评价左室舒张功能减退中具有重要价值。且在评价不同阶段左室舒张功能障碍时,二尖瓣环前壁及下壁分别具有不同意义。 AIM:To explore the significance of mitral annular (anterior and inferior) velocity profile measured with Doppler Tissue Imaging(DTI) at different stages of left ventricular diastolic dysfunction. METHODS:The mitral annular/anterior wall (MVA/AW) and mitral annular/inferior wall (MVA/IW) velocity profile was measured with DTI in 100 patients with diastolic dysfunction at different stages and 30 normal persons,which was compared with mitral inflow pulsive wave (PW) Doppler velocity. RESULTS:①In the relaxation decreased period,the PW E/A,MVA/AW E/A and MVA/IW E/A were all decreased as compared with the normal controls(P< 0.01).The coincidence ratio in MVA/AW E/A and PW E/A was higher than that in MVA/IW(100%and 60%, P< 0.01). ②There was no significant difference between the PW E/A and normal groups in pseudo normal period(P >0.05), while the MVA/AW E/A and MVA/IW E/A were significantly decreased(P< 0.01),and the coincidence ratio in MVA/AW and PW E/A was lower than that in the latter (20%and 40%, P< 0.01);③The E/A in the three groups was all higher than that in the normal control group(P< 0.01),but the coincidence ratio in MVA/IW and PW E/A was significantly higher than that in MVA/AW E/A(89%and 22%, P< 0.01). CONCLUSION:Mitral annular velocity profile detected by DTI has important significance in assessing the left ventricular diastolic dysfunction,and there are different values between mitral annular/anterior and inferior at different stages of left ventricular diastolic dysfunction.
出处 《中国临床康复》 CSCD 2004年第24期4992-4993,共2页 Chinese Journal of Clinical Rehabilitation
  • 相关文献

参考文献8

  • 1Cohen GI, Pietrolungo JF, Thomas JD, et al. A practical guide to assessment of ventricular biastolic function using Doppler echocardiography. JACC 1996; 27(7); 1753-60
  • 2Appleton CP, Hatla K, Popp RL, et al.Relation of transmitral flow velocity patterns to left ventricular diastolic function new insights from a combined hemodynamic and Doppler echocardiography study. JACC 1988; 12:426-40
  • 3Rossvol O, Hatla LK. Pulmonary venous fiow velocities recorded by Doppler ultrasound; relation to left ventricular diastolic pressures. JACC 1993; 21; 1687-96
  • 4Stoddard MF, Pearson AC, Kern M J, et al. Influence of alteration in preload on the pattern of left ventricular diastolic filling as assessed by Doppler echocardiography in humans. Circulation 1989; 79:1226-36
  • 5Keren G, Sonnenblick EH, Lejemtel TH, et al. Mitral annulus motion, relation to pulmonary venous and transmitral flow in normal subject: and in patients with dilated cardiomyopathy. Circulation 1988; 78:621-9
  • 6吴戴红,杜微云.应用多普勒组织成像技术观察正常人心脏室壁运动的频谱特征[J].中国临床康复,2004,8(9):1649-1651. 被引量:5
  • 7邢晋放,曹铁生,段云友.三维彩色多普勒超声成像评价颈动脉狭窄程度的准确性研究[J].中国临床康复,2004,8(12):2256-2257. 被引量:10
  • 8田新桥,钱蕴秋,周晓东,张军,李军,朱霆,朱永胜,刘丽文.多普勒组织成像评价冠心病患者的左室整体舒张功能[J].中国超声医学杂志,2000,16(8):571-573. 被引量:20

二级参考文献24

  • 1De Simone R, Glombitza G, Vahl CF, et al. Three-dimensional color Doppler reconstruction and its clinical applications. Echocardiography 2000; 17 (8): 765 - 71.
  • 2Bucek RA, Reiter M, Dirisamer A, et al. Three-dimensional color Doppler sonography in carotid artery stenosis. Am J Neuroradiol 2003; 24 (7): 1294 -9.
  • 3Sugeng L, Spencer KT, Mor-Avi V, et al. Dynamic three-dimensional color flow Doppler: an improved technique for the assessment of mitral regurgitation. Echocardiography 2003:20 (3) : 265 - 73.
  • 4Xiaokui T. Schwartz GA. Rusk RA, et al. A digital 3-dimensional method for computing great arteu- flows: in ritro validation studies. J Am Soc Echocardiogr 2000; 13(9): 841 -8.
  • 5Li XK, Shiota T, Delabays A, et al. Flow convergence flow rate from 3-dimersional reconstruction of color Dopper flow maps for computing transvalvular regurgitant flows without geometric assumptions : an in vitro quantitative flow study. J Am Soc Echocardioxr 1999; 12:1035- 44.
  • 6Pai R G,J Am Soc Echocardiogr,1998年,11卷,2期,105页
  • 7Sohn D W,JACC,1997年,30卷,2期,474页
  • 8Pai R G,Am J Cardiol,1991年,222页
  • 9Sugeng L,Spencer KT,Mor-Avi V,et al.Dynamic three-dimensional color flow Doppler:an improved technique for the assessment of mitral regurgitation.Echocardiography 2003;20(3):265-73
  • 10Xiaokui T,Schwartz GA,Rusk RA,et al.A digital 3-dimensional method for computing great artery flows:in vitro validation studies.J Am Soc Echocardiogr 2000;13(9):841-8

共引文献32

同被引文献4

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部