摘要 对蒲山电厂凝汽器铜管的腐蚀泄漏原因进行了试验和腐蚀过程分析,找出了原始铜管存在的残碳膜和晶体缺陷是腐蚀的诱发因素,采取了针对性的镀膜处理和一系列运行管理措施。达到了预期的效果。 The cause of corrosion leakage of condenser copper tubes in Pushan Power Plant was tested and the corrosion process was analyzed,it was found that the residual carbon film existing on the original copper tubes and the crystal defects were the induced factors of corrosion.The cleaning--film coating treatment and a series of operation management measures were taken, with the expected effects achieved.
出处 《中国电力》 CSCD 北大核心 2004年第8期28-30,共3页 Electric Power
关键词 残碳膜 凝汽器铜管 腐蚀分析 residual carbon film condenser copper tube corrosion analysis
  • 相关文献

参考文献1

  • 1林乐耘 刘增才.凝汽器用黄铜管材的加工组织缺陷及其腐蚀失效行为[J].稀有金属,1998,(4).