研究了TTA新体系的化学发光特性。依据Ni^(2+)的催化作用,通过条件优化实验,建立了测定Ni^(2+)的化学发光新方法。方法检出限为3.0ng/ml Ni^(2+),线性范围为4×10^(-9)-4×10^(-6)g/mL;对0.1μg/ml Ni^(2+)进行10次重复测定的相对标准偏差为0.94%。方法应用于水中镍的测定,结果良好。
The present paper has studied the chemiluminescence reaction of TTA system. The determination of nickel based on its catalysis has been proposed by optimizing chemiluminescence conditions. The linear response of nickelous concentration is 4.0×10^(-6)g/ml to 4.0×10^(-9)/ml with a detection limit of 3.0ng/ml, and the variation coefficient at a nickelous concentration of 0.1μg/ml Ni^(2+) ( n=10) is 0.94%. The method has been satisfactorily applied to the determination of nickel in water.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1993年第3期113-116,共4页
Spectroscopy and Spectral Analysis
基金
国家自然科学基金~~
关键词
TTA
化学发光
镍离子
The novel chemiluminescence of TTA, Nickel ion