期刊文献+

AO斜T型钛钢板治疗桡骨远端关节内骨折21例 被引量:1

Treatment of intra-articular fractures of distal radius by internal fixation with AO declining T-shaped titanium plate in 21 cases
下载PDF
导出
摘要 目的 探讨AO斜T型钛钢板治疗桡骨远端关节内骨折的疗效。方法 对 2 1例桡骨远端关节内骨折切开复位 ,应用AO斜T型钛钢板内固定。结果 术后随访 2~ 14个月 ,优 11例 ,良 9例 ,优良率 95 2 4 %。 Objective To evaluate the clinical treatment of intra-articular fractures of distal radius by open reduction and internal fixation with AO declining T-shaped titanium plate. Methods 21 cases of intra-articular fractures of the distal radius were treated by open reduction, internal fixation with AO declining T-shaped titanium plate and early functional exercise. Results All cases were followed up for 2~14 months. The results were excellent in 11 cases and good in 9, and the excellent and good rate was 95.24%. Conclusion It is a reliable way to treat intra-articular fractures of distal radius by open reduction and internal fixation with AO declining T-shaped titanium plate.
出处 《临床骨科杂志》 2004年第3期285-286,共2页 Journal of Clinical Orthopaedics
关键词 AO斜T型钛钢板 桡骨骨折 骨折固定术 AO declining T-shaped titanium plate radius fractures fracture fixation, internal
  • 相关文献

参考文献5

  • 1Skinner HB. Current diagnosis and treatment in orthopedics[M].1st ed, Prenlice-Hall:International Inc,1995:69~83
  • 2白建忠,俞思勤,陈舰,郁凯乐.B、C型桡骨远端骨折的治疗[J].临床骨科杂志,2003,6(2):141-143. 被引量:43
  • 3Baratz ME, Des Jardins JD, Anderson DD et al. Displaced intra-articular fractures of the distal radius:the effect of fracture displacement on contact stresses in a cadaver model[J]. J Hand Surg [Am], 1996;21(2):183~188
  • 4Trumble TE,Schmitt SR,Vedder NB. Factors affecting functional outcome of displaced infra-articular distal radius fractures[J]. J Hand Surg [Am], 1994;19(2):325~340
  • 5郑华龙,吴富章,郭涛,蔡靖宇,张勇.桡骨远端不稳定性骨折手术与保守治疗疗效比较[J].临床骨科杂志,2003,6(3):211-213. 被引量:28

二级参考文献22

  • 1贡小英,荣国威,耿向苏,安贵生.Colles骨折与腕关节不稳定[J].中华外科杂志,1994,32(2):87-89. 被引量:16
  • 2Swigart CR, Wolfe SW. Limited incision open techniques for distal radius fracture management[ J]. Orthop Clin North Am, 2001 ;32(2) :317 -327.
  • 3Fitoussi F, Ip WY, Chow SP. Treatment of displaced intra-aticular fractures of the distal end of the radius with plates[ J], J Bone Joint Surg Am, 1997 ;79 ( 9 ) : 1303-1312.
  • 4Kamano M, Honda Y, Kazuki K et al. Palmar plating for dorsally displaced fractures of the distal radius [ J ]. Clin Orthop, 2002;(397) :403- 408.
  • 5Sun JS, Chang CH, Wu CC et al. Extra-articular deformity in distal radial fractures treated by external fixation [ J ]. Can J Surg, 2001 ;44(4) :289 -294.
  • 6Broos PL, Fourneau IA, Stoffelen DV. Fractures of the distal radius, current concepts for treatment[ J]. Acta Orthop Belg, 2001 ;67(3) :211 -218.
  • 7Christensen OM, Christiansen TC, Krasheninnikoff Met al. Plaster cast compared with bridging external fixation for distal radiusfractures of the Colles' type[J]. Int Orthop, 2001 ;24(6) :358 -360.
  • 8Kaempffe FA, Walker KM. External fixation for distal radius fractures: effect of distraction on outcome [J]. Clin Orthop, 2000;(380) :220-225.
  • 9Kapoor H, Agarwal A, Dhaon BK. Displaced intra - articular fractures of distal radius: a comparative evaluationof results following closed reduction, external fixation and open reduction with internal fixation[J]. Injury, 2000;31 (2) :75-79.
  • 10Dee W, Klein W, Rieger H. Reduction techniques in distal radius fractures[J]. Injury, 2000;31 ( Suppl 1 ) :48-55.

共引文献68

同被引文献3

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部