期刊文献+

Bolustrack在3D CE MRA中的应用 被引量:3

Application of Bolustrack in three-dimentional contrast-enhanced MR angiography
下载PDF
导出
摘要 目的:探讨Bolustrack在3DCEMRA中的应用优势。方法:收集32例疑有胸、腹部动脉及颈部动脉病变的患者,使用常规剂量造影剂0.2mmol?kg;8例健康志愿者,使用前者一半的剂量0.1mmol?kg,均在Bolustrack引导下行3DCEMRA扫描,后期利用MIP重建。结果:40例均获得满意的动脉血管影像,满足诊断需要,诊断符合率100%。结论:利用Bolustrack能准确地观察造影剂到达靶血管的峰团时间,抓住动脉期成像的最佳时机,使动脉成像的成功率达到100%;还可以将造影剂用量降到最低。它的应用使3DCEMRA的技术更趋完善。 Objective: To discuss the application value of Bolustrack in three-dimensional contrast-enhanced MRA(3D CE MRA). Methods: Thirty-two patients suspected with thoracic, abdominal and cervical arterial diseases(using Gd-DTPA, dosage 0.2mmolkg) and 8 healthy volunteers(Gd-DTPA, dosage 0.1mmolkg) were performed with 3D CE MRA scanning guided by Bolustrack technique. Results: All cases got satisfied vascular images in arterial phase. The diagnostic coincidence rate is 100%. Conclusions: Bolustrack technique makes it possible to make sure about the optimal enhancement time and to obtain optimal CE MRA images. It also greatly improves the quality of images as well as the accuracy of diagnosis.
出处 《中国临床医学影像杂志》 CAS 2004年第9期530-532,共3页 Journal of China Clinic Medical Imaging
关键词 血管疾病 磁共振血管造影术 vascular diseases magnetic resonance angiography
  • 相关文献

参考文献8

  • 1[1]Glockner JF. Three-dimensional gadolinium-enhanced MR angiography: applications for abdominal imaging [J]. Radiographics,2001, 21 (2): 357-370.
  • 2[2]Nishida N, Sakai G, Morimoto A. Gadolinium enhanced three-dimensional magnetic resonance portography with subtraction[J].BrJ Radiol, 2001, 74 (2): 111-117.
  • 3[3]Goldfarb JW, Prasad PV, Griswold MA, et al. Dynamic three-dimensional magnetic resonance anglography and perfusion: implementation and preliminary experience [J]. J Magn R eson Imaging,2000, 11: 201-207.
  • 4[4]Grist TM. MRA of the abdominal aorta and lower extremities[J]. J Magn Reson Imaging, 2000, 11: 32-43.
  • 5[5]Sadick M, Dienl SJ, Lehmann KJ, et al. Evaluation of breath-hold contrast-enhanced 3D magnetic resonance angiography technique for imaging visceral abdominal arteries and veins[J]. Invest Radiol, 2000, 35 (2): 111-117.
  • 6[6]Schoenberg SO, Bock M, Knopp MV, et al. Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold[J]. Radiology, 1999, 211: 667-679.
  • 7[7]谢敬霞.核磁共振新技术研究与临床应用[M].北京:北京医科大学出版社出版,2002.246-264.
  • 8[8]Martin RP, Thomas M, Grist JFD. 3D Contrast MR Angiography[M]. Springer, 1999. 48-111.