UHT机流量测定与恒温杀菌时间的验证 被引量:3

Determination of flow in UHT sterilizer and verification of constant-temperature sterilization time
下载PDF
导出
摘要 当泵的流量设定为常数后 ,通过测定在单位时间内通过UHT机恒温管的水的重量后得出质量流量ms,然后根椐恒温管的内径d和水的密度ρ计算出流速u ,再通过恒温管的长度L计算出杀菌时间t。 When the flow of the pump is set as the constant, the mass flow m s is obtained by measuring the weight of water passing through the constant-temperature pipes of the UHT sterilizer in unit time. Then, according to the inner diameter d of the constant-temperature pipes and the density of water ρ, velocity of flow u is calculated. After that, the scheduled time t is got from the length L of the constant-temperature pipes. It's required that the scheduled time t accord with the critical limit (CL).
出处 《饮料工业》 2004年第4期42-45,共4页 Beverage Industry
关键词 UHT机 质量流量 杀菌时间 杀菌温度 UHT sterilizer mass flow scheduled time scheduled temperature critical limit (CL)